Independent picks. Sized with plain math from CDC, FEMA and maker specs.
Outage OutfitterFind my power station
RV solar, sized from the spec sheets

Fit your RV with solar. Every part, every wire, every fuse.

Tell us what you run and where you camp. We size the battery, panels, controller, inverter, fuses and cable, then show a complete kit you can buy today. Every number traces to a manufacturer sheet, the Coast Guard wiring table or the electrical code.

  1. 1Panelsin series on the roof
  2. 2String fuseprotects the roof wire
  3. 3MPPTturns sun into charge
  4. 4LiFePO4the tank you live from
  5. 5Main fusewithin 7 in of the battery
  6. 6Inverter120 V outlets
Start here

How do you camp?

Start from the closest kit, then tap what you actually own. The kit below updates as you go.

Essentials What every RV runs

Comfort Air, heat and sleep

Work and play Internet, screens, laptops

Kitchen The 120 V heavy hitters

Big loads Possible, but plan for it

A ZIP gives month-by-month sun from NREL PVWatts.
Days without sun
AS/NZS 4509.2 plans 2 days when an engine or generator can take over, 4 to 5 with none; IEEE 1562 plans 5 to 7 for non-critical loads. One day is a weekend with a drive home.A 50 A DC-DC charger puts back 640 Wh an hour on the road.
Clear roof for panels
After vents, AC and skylights; rig figures are rough, so measure yours.
A day of your list
0 Wh

    Recommended kit

        Add the kit to your Amazon cart

        Opens Amazon with the parts ready to add. Nothing is bought until you check out.

        Wiring diagram and printable planSee every partEvery part of every kit
        Your exact numbers
        Battery
        Ah LiFePO4
        Solar
        W of panels
        MPPT
        A
        Inverter
        Inverter fuse
        Inverter cable

        Each line is the published stand-alone PV method with your numbers; every result rounds up to the next size you can buy. Battery Ah = daily Wh × days of autonomy ÷ 12.8 V ÷ 80% usable (IEEE 1013 and the Sandia handbook). Panels W = daily Wh × 1.2 array-to-load ratio (IEEE 1562) ÷ peak sun hours ÷ 0.86 PVWatts losses ÷ 0.92 battery round trip. MPPT A = panel W ÷ 14.4 V (Victron). Inverter W = 120 V loads that run together × 1.25 (NEC continuous-load rule). Fuse = 125% of inverter current, next standard size (NEC 690.8). Where each rule comes from.

        Your plan

        Weekender kit

        Wiring diagram

        positive negative panel string. Fuse and wire sizes are the kit's, from the makers' sheets and the rules below.

        RolePartQtyAmazon

        0 Wh a daySee my kit ↓
        Every part

        Three sizes, four brands, part by part

        Keep the controller, monitor and inverter from one maker and they share one app and one support line. Fuses, bus bars, switches and cable are Blue Sea and WindyNation in every kit; those are brand-neutral. Buy buttons go to Amazon; as an Amazon Associate we earn from qualifying purchases at no extra cost to you.

        Weekender One 200 W panel, 100 Ah of LiFePO4, a 20 to 30 A MPPT and a 1,000 W inverter for the occasional AC gadget.

        Renogy

        200 W · 100 Ah · 1,000 W · 15 parts

        One maker for panels, controller, battery, inverter and monitor. Specs are as published by each maker on 2026-10-13; click the source to check.

        RolePartWhy this oneQtyBuy
        Solar panelRenogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source1Buy on Amazon
        MPPT charge controllerRenogy Rover 2 20 A MPPT (RCC-M10020-C2)Renogy Rover 2 20 A MPPT (RCC-M10020-C2)20 A, 15 to 100 V PV input, 300 W of panels at 12 V, built-in Bluetooth source1Buy on Amazon
        LiFePO4 batteryRenogy 12 V 100 Ah Pro, Bluetooth and self-heating (RBT12100LFP-BT)Renogy 12 V 100 Ah Pro, Bluetooth and self-heating (RBT12100LFP-BT)100 Ah, 100 A BMS, 5,000 cycles at 80% DoD, self-heating below 41 °F, 26.9 lb source1Buy on Amazon
        Pure sine inverter (optional)Renogy 1000 W 12 V pure sine wave (P2)Renogy 1000 W 12 V pure sine wave (P2)1,000 W continuous, 2,000 W surge for 1 s, under 1 A no-load, 4 AWG 3 ft cables included source1Buy on Amazon
        Battery monitorRenogy 500 A battery monitor with shunt (RBM500)Renogy 500 A battery monitor with shunt (RBM500)500 A shunt, 10 to 120 V, ±1% capacity accuracy, backlit display on a 20 ft lead source1Buy on Amazon
        Battery and inverter cable (if the included cables are too short)WindyNation 4 AWG welding and battery cableWindyNation 4 AWG welding and battery cable4 AWG pure copper, 600 V, 105 °C EPDM; 160 A at 105 °C per 33 CFR 183.425 source1Buy on Amazon
        Inverter fuse and holderBlue Sea Systems ANL fuse 150 A (5127) in ANL block (5005)Blue Sea Systems ANL fuse 150 A (5127) in ANL block (5005)150 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 1000 W source1Buy on Amazon
        Bus bars (two)Blue Sea Systems Common 150 A BusBar, 10 gang (2301)Blue Sea Systems Common 150 A BusBar, 10 gang (2301)150 A DC continuous, 48 V DC, 1/4 in stud; one positive, one negative source2Buy on Amazon
        Battery disconnect switchBlue Sea Systems m-Series mini on-off switch (6006)Blue Sea Systems m-Series mini on-off switch (6006)300 A continuous, 500 A for 5 min, 48 V DC source1Buy on Amazon
        12 V fuse blockBlue Sea Systems ST Blade fuse block, 6 circuits (5025)Blue Sea Systems ST Blade fuse block, 6 circuits (5025)30 A per circuit, 100 A per block, 32 V DC; feeds lights, pump, fan, USB source1Buy on Amazon
        PV string fuseRenogy MC4 in-line fuse holder (15 or 20 A)Renogy MC4 in-line fuse holder (15 or 20 A)10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source1Buy on Amazon
        PV disconnect breakerRenogy 1P DC miniature circuit breaker, 32 ARenogy 1P DC miniature circuit breaker, 32 A10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source1Buy on Amazon
        Panel mountsRenogy Z bracket set of 4Renogy Z bracket set of 4Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source1Buy on Amazon
        Roof cable entryRenogy Double cable entry glandRenogy Double cable entry glandUV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source1Buy on Amazon
        PV cable (roof to controller)Renogy 10 AWG MC4 extension cable pairRenogy 10 AWG MC4 extension cable pair10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source1Buy on Amazon

        Rich Solar

        200 W · 100 Ah · 1,000 W · 15 parts

        One maker for panels, controller, battery, inverter, monitor and roof hardware. Specs are as published by each maker on 2026-10-13; click the source to check.

        RolePartWhy this oneQtyBuy
        Solar panelRich Solar MEGA 200 (RS-M200)Rich Solar MEGA 200 (RS-M200)200 W, Voc 21.8 V, Vmp 18.4 V, Isc 11.6 A, 58.7 × 26.8 in, 24 lb source1Buy on Amazon
        MPPT charge controllerRich Solar BRAVO PRO 30 flush-mount MPPT (RS-MPPT30FB)Rich Solar BRAVO PRO 30 flush-mount MPPT (RS-MPPT30FB)30 A, 8 to 100 V PV input, 500 W of panels recommended at 12 V, Bluetooth, UL 1741 source1Buy on Amazon
        LiFePO4 batteryRich Solar ALPHA 1 12 V 100 Ah, Bluetooth and internal heater (RS-B121S)Rich Solar ALPHA 1 12 V 100 Ah, Bluetooth and internal heater (RS-B121S)100 Ah, 1,280 Wh, 100 A continuous discharge, 5,000+ cycles at 80% DoD, 100 W heater, 24 lb The bigger kits run several in parallel: Rich Solar's ALPHA 2 200 Ah page lists only 100 A of discharge, which cannot feed a 2,000 W inverter on its own. source1Buy on Amazon
        Pure sine inverter (optional)Rich Solar NOVA PURE 1K 12 V (RS-V1P12)Rich Solar NOVA PURE 1K 12 V (RS-V1P12)1,000 W continuous, 2,000 W surge, over 88% peak efficiency, under 1 A no-load, UL 458, 5.3 lb Rich Solar publishes no fuse or cable size for it, so the kit uses the 125% rule: 1,000 W at 12.8 V and 85% is 92 A, times 1.25 is 115 A, so a 150 A fuse on 4 AWG, the same pair Renogy specifies for its 1,000 W. source1Buy on Amazon
        Battery monitorRich Solar 500 A battery monitor with shunt (RS-BM500)Rich Solar 500 A battery monitor with shunt (RS-BM500)500 A shunt, 8 to 120 V, ±1% capacity, voltage and current accuracy source1Buy on Amazon
        Battery and inverter cable (if the included cables are too short)WindyNation 4 AWG welding and battery cableWindyNation 4 AWG welding and battery cable4 AWG pure copper, 600 V, 105 °C EPDM; 160 A at 105 °C per 33 CFR 183.425 source1Buy on Amazon
        Inverter fuse and holderBlue Sea Systems ANL fuse 150 A (5127) in ANL block (5005)Blue Sea Systems ANL fuse 150 A (5127) in ANL block (5005)150 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 1000 W source1Buy on Amazon
        Bus bars (two)Blue Sea Systems Common 150 A BusBar, 10 gang (2301)Blue Sea Systems Common 150 A BusBar, 10 gang (2301)150 A DC continuous, 48 V DC, 1/4 in stud; one positive, one negative source2Buy on Amazon
        Battery disconnect switchBlue Sea Systems m-Series mini on-off switch (6006)Blue Sea Systems m-Series mini on-off switch (6006)300 A continuous, 500 A for 5 min, 48 V DC source1Buy on Amazon
        12 V fuse blockBlue Sea Systems ST Blade fuse block, 6 circuits (5025)Blue Sea Systems ST Blade fuse block, 6 circuits (5025)30 A per circuit, 100 A per block, 32 V DC; feeds lights, pump, fan, USB source1Buy on Amazon
        PV string fuseRich Solar In-line fuse holder, 20 A (RS-SC20F)Rich Solar In-line fuse holder, 20 A (RS-SC20F)10, 15, 20 or 30 A options, 1000 V DC, IP67. The MEGA 200 string needs 20 A (11.6 A × 1.56 = 18.1 A) source1Buy on Amazon
        PV disconnect breakerRenogy 1P DC miniature circuit breaker, 32 ARenogy 1P DC miniature circuit breaker, 32 A10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source1Buy on Amazon
        Panel mountsRich Solar Z-brackets with screws, pack of four (RS-ZB4C)Rich Solar Z-brackets with screws, pack of four (RS-ZB4C)Anodized aluminum; one pack per panel, made for the MEGA panels source1Buy on Amazon
        Roof cable entryRich Solar Cable entry housing (RS-C2B)Rich Solar Cable entry housing (RS-C2B)UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source1Buy on Amazon
        PV cable (roof to controller)Rich Solar 10 AWG solar extension cable pair, 20 ft (RS-20102)Rich Solar 10 AWG solar extension cable pair, 20 ft (RS-20102)10 AWG, 1000 V DC, MC4-compatible ends; 20 ft pair covers most roofs source1Buy on Amazon

        Victron + Battle Born

        200 W · 100 Ah · 1,000 W · 15 parts

        Victron controller, monitor and inverter in one app; Battle Born batteries built in Reno. Panels are Renogy, since Victron sells none. Specs are as published by each maker on 2026-10-13; click the source to check.

        RolePartWhy this oneQtyBuy
        Solar panelRenogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source1Buy on Amazon
        MPPT charge controllerVictron Energy SmartSolar MPPT 100/20Victron Energy SmartSolar MPPT 100/2020 A, 100 V max PV, 290 W nominal PV at 12 V, Bluetooth source1Buy on Amazon
        LiFePO4 batteryBattle Born 100 Ah 12 V LiFePO4 (BB10012)Battle Born 100 Ah 12 V LiFePO4 (BB10012)100 Ah, 100 A continuous, 200 A surge for 30 s, 3,000 to 5,000 cycles, cold-charging protection, 31 lb, made in Reno Battle Born's one 12 V size above 100 Ah is the 270 Ah GC3; the kits add 100 Ah units in parallel instead. source1Buy on Amazon
        Pure sine inverter (optional)Victron Energy Phoenix Inverter 12/1200 VE.Direct, 120 VVictron Energy Phoenix Inverter 12/1200 VE.Direct, 120 V1,200 VA: 1,000 W continuous at 25 °C, 850 W at 40 °C, 2,200 W peak, 91% max efficiency, 10 W no-load; internal 200 A fuse Victron's manual requires a fuse near the battery for cable runs over 1.5 m and for the UL units, and calls for 25 mm² cable, between 4 and 2 AWG; the kit lists 1/0 AWG, the next size we carry, with a 150 A fuse by the 125% rule. source1Buy on Amazon
        Battery monitorVictron Energy SmartShunt 500 AVictron Energy SmartShunt 500 A500 A shunt, 6.5 to 70 V, Bluetooth app shows state of charge source1Buy on Amazon
        Battery and inverter cableWindyNation 1/0 AWG welding and battery cable, 10 ft red and 10 ft blackWindyNation 1/0 AWG welding and battery cable, 10 ft red and 10 ft black1/0 AWG pure copper, 600 V, 105 °C EPDM; 285 A at 105 °C per 33 CFR 183.425 source1Buy on Amazon
        Inverter fuse and holderBlue Sea Systems ANL fuse 150 A (5127) in ANL block (5005)Blue Sea Systems ANL fuse 150 A (5127) in ANL block (5005)150 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 1000 W source1Buy on Amazon
        Bus bars (two)Blue Sea Systems Common 150 A BusBar, 10 gang (2301)Blue Sea Systems Common 150 A BusBar, 10 gang (2301)150 A DC continuous, 48 V DC, 1/4 in stud; one positive, one negative source2Buy on Amazon
        Battery disconnect switchBlue Sea Systems m-Series mini on-off switch (6006)Blue Sea Systems m-Series mini on-off switch (6006)300 A continuous, 500 A for 5 min, 48 V DC source1Buy on Amazon
        12 V fuse blockBlue Sea Systems ST Blade fuse block, 6 circuits (5025)Blue Sea Systems ST Blade fuse block, 6 circuits (5025)30 A per circuit, 100 A per block, 32 V DC; feeds lights, pump, fan, USB source1Buy on Amazon
        PV string fuseRenogy MC4 in-line fuse holder (15 or 20 A)Renogy MC4 in-line fuse holder (15 or 20 A)10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source1Buy on Amazon
        PV disconnect breakerRenogy 1P DC miniature circuit breaker, 32 ARenogy 1P DC miniature circuit breaker, 32 A10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source1Buy on Amazon
        Panel mountsRenogy Z bracket set of 4Renogy Z bracket set of 4Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source1Buy on Amazon
        Roof cable entryRenogy Double cable entry glandRenogy Double cable entry glandUV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source1Buy on Amazon
        PV cable (roof to controller)Renogy 10 AWG MC4 extension cable pairRenogy 10 AWG MC4 extension cable pair10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source1Buy on Amazon

        Value mix

        200 W · 100 Ah · 1,000 W · 15 parts

        Victron controller and monitor, LiTime battery, Renogy panels and inverter: the lowest price for the same numbers. Specs are as published by each maker on 2026-10-13; click the source to check.

        RolePartWhy this oneQtyBuy
        Solar panelRenogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source1Buy on Amazon
        MPPT charge controllerVictron Energy SmartSolar MPPT 100/20Victron Energy SmartSolar MPPT 100/2020 A, 100 V max PV, 290 W nominal PV at 12 V, Bluetooth source1Buy on Amazon
        LiFePO4 batteryLiTime 12 V 100 Ah LiFePO4 (Group 31)LiTime 12 V 100 Ah LiFePO4 (Group 31)100 Ah, 1,280 Wh, 100 A BMS, 4,000 cycles at 100% DoD, 24 lb source1Buy on Amazon
        Pure sine inverter (optional)Renogy 1000 W 12 V pure sine wave (P2)Renogy 1000 W 12 V pure sine wave (P2)1,000 W continuous, 2,000 W surge for 1 s, under 1 A no-load, 4 AWG 3 ft cables included source1Buy on Amazon
        Battery monitorVictron Energy SmartShunt 500 AVictron Energy SmartShunt 500 A500 A shunt, 6.5 to 70 V, Bluetooth app shows state of charge source1Buy on Amazon
        Battery and inverter cable (if the included cables are too short)WindyNation 4 AWG welding and battery cableWindyNation 4 AWG welding and battery cable4 AWG pure copper, 600 V, 105 °C EPDM; 160 A at 105 °C per 33 CFR 183.425 source1Buy on Amazon
        Inverter fuse and holderBlue Sea Systems ANL fuse 150 A (5127) in ANL block (5005)Blue Sea Systems ANL fuse 150 A (5127) in ANL block (5005)150 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 1000 W source1Buy on Amazon
        Bus bars (two)Blue Sea Systems Common 150 A BusBar, 10 gang (2301)Blue Sea Systems Common 150 A BusBar, 10 gang (2301)150 A DC continuous, 48 V DC, 1/4 in stud; one positive, one negative source2Buy on Amazon
        Battery disconnect switchBlue Sea Systems m-Series mini on-off switch (6006)Blue Sea Systems m-Series mini on-off switch (6006)300 A continuous, 500 A for 5 min, 48 V DC source1Buy on Amazon
        12 V fuse blockBlue Sea Systems ST Blade fuse block, 6 circuits (5025)Blue Sea Systems ST Blade fuse block, 6 circuits (5025)30 A per circuit, 100 A per block, 32 V DC; feeds lights, pump, fan, USB source1Buy on Amazon
        PV string fuseRenogy MC4 in-line fuse holder (15 or 20 A)Renogy MC4 in-line fuse holder (15 or 20 A)10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source1Buy on Amazon
        PV disconnect breakerRenogy 1P DC miniature circuit breaker, 32 ARenogy 1P DC miniature circuit breaker, 32 A10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source1Buy on Amazon
        Panel mountsRenogy Z bracket set of 4Renogy Z bracket set of 4Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source1Buy on Amazon
        Roof cable entryRenogy Double cable entry glandRenogy Double cable entry glandUV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source1Buy on Amazon
        PV cable (roof to controller)Renogy 10 AWG MC4 extension cable pairRenogy 10 AWG MC4 extension cable pair10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source1Buy on Amazon

        Full-timer Three 200 W panels in series, 200 Ah of LiFePO4, a 60 A MPPT and a 2,000 W class inverter that runs an RV microwave.

        Renogy

        600 W · 200 Ah · 2,000 W · 15 parts

        One maker for panels, controller, battery, inverter and monitor. Specs are as published by each maker on 2026-10-13; click the source to check.

        RolePartWhy this oneQtyBuy
        Solar panelRenogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source3Buy on Amazon
        MPPT charge controllerRenogy Rover 60 A MPPT (RNG-CTRL-RVR60)Renogy Rover 60 A MPPT (RNG-CTRL-RVR60)60 A, 140 V max PV input, 800 W of panels at 12 V; Bluetooth with the BT-2 module source1Buy on Amazon
        LiFePO4 batteryRenogy 12 V 100 Ah Pro, Bluetooth and self-heating (RBT12100LFP-BT)Renogy 12 V 100 Ah Pro, Bluetooth and self-heating (RBT12100LFP-BT)100 Ah, 100 A BMS, 5,000 cycles at 80% DoD, self-heating below 41 °F, 26.9 lb source2Buy on Amazon
        Pure sine inverterRenogy 2000 W 12 V pure sine wave (P2)Renogy 2000 W 12 V pure sine wave (P2)2,000 W continuous, 4,000 W surge for 1 s, under 2 A no-load, 1/0 AWG 3 ft cables included source1Buy on Amazon
        Battery monitorRenogy 500 A battery monitor with shunt (RBM500)Renogy 500 A battery monitor with shunt (RBM500)500 A shunt, 10 to 120 V, ±1% capacity accuracy, backlit display on a 20 ft lead source1Buy on Amazon
        Battery and inverter cable (if the included cables are too short)WindyNation 1/0 AWG welding and battery cable, 10 ft red and 10 ft blackWindyNation 1/0 AWG welding and battery cable, 10 ft red and 10 ft black1/0 AWG pure copper, 600 V, 105 °C EPDM; 285 A at 105 °C per 33 CFR 183.425 source1Buy on Amazon
        Inverter fuse and holderBlue Sea Systems ANL fuse 250 A (5131) in ANL block (5005)Blue Sea Systems ANL fuse 250 A (5131) in ANL block (5005)250 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 2000 W source1Buy on Amazon
        Bus bars (two)Blue Sea Systems MaxiBus 250 A (2127)Blue Sea Systems MaxiBus 250 A (2127)250 A continuous, 48 V DC, four 5/16 in studs; one positive, one negative source2Buy on Amazon
        Battery disconnect switchBlue Sea Systems m-Series mini on-off switch (6006)Blue Sea Systems m-Series mini on-off switch (6006)300 A continuous, 500 A for 5 min, 48 V DC source1Buy on Amazon
        12 V fuse blockBlue Sea Systems ST Blade fuse block, 12 circuits (5026)Blue Sea Systems ST Blade fuse block, 12 circuits (5026)30 A per circuit, 100 A per block, 32 V DC, negative bus source1Buy on Amazon
        PV string fuseRenogy MC4 in-line fuse holder (15 or 20 A)Renogy MC4 in-line fuse holder (15 or 20 A)10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source1Buy on Amazon
        PV disconnect breakerRenogy 1P DC miniature circuit breaker, 32 ARenogy 1P DC miniature circuit breaker, 32 A10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source1Buy on Amazon
        Panel mountsRenogy Z bracket set of 4Renogy Z bracket set of 4Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source3Buy on Amazon
        Roof cable entryRenogy Double cable entry glandRenogy Double cable entry glandUV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source1Buy on Amazon
        PV cable (roof to controller)Renogy 10 AWG MC4 extension cable pairRenogy 10 AWG MC4 extension cable pair10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source1Buy on Amazon

        Rich Solar

        600 W · 200 Ah · 2,000 W · 15 parts

        One maker for panels, controller, battery, inverter, monitor and roof hardware. Specs are as published by each maker on 2026-10-13; click the source to check.

        RolePartWhy this oneQtyBuy
        Solar panelRich Solar MEGA 200 (RS-M200)Rich Solar MEGA 200 (RS-M200)200 W, Voc 21.8 V, Vmp 18.4 V, Isc 11.6 A, 58.7 × 26.8 in, 24 lb source3Buy on Amazon
        MPPT charge controllerRich Solar BRAVO 60 MPPT (RS-MPPT60P)Rich Solar BRAVO 60 MPPT (RS-MPPT60P)60 A, 100 V max PV open-circuit voltage, 900 W of panels recommended at 12 V, Bluetooth The Off-grid kit wires its four MEGA 200 as two strings of two (about 50 V cold). Four in one string would be about 99 V on a −10 °C morning, too close to the 100 V limit. source1Buy on Amazon
        LiFePO4 batteryRich Solar ALPHA 1 12 V 100 Ah, Bluetooth and internal heater (RS-B121S)Rich Solar ALPHA 1 12 V 100 Ah, Bluetooth and internal heater (RS-B121S)100 Ah, 1,280 Wh, 100 A continuous discharge, 5,000+ cycles at 80% DoD, 100 W heater, 24 lb The bigger kits run several in parallel: Rich Solar's ALPHA 2 200 Ah page lists only 100 A of discharge, which cannot feed a 2,000 W inverter on its own. source2Buy on Amazon
        Pure sine inverterRich Solar NOVA PURE 2K 12 V (RS-V2P12)Rich Solar NOVA PURE 2K 12 V (RS-V2P12)2,000 W continuous, 4,000 W surge, over 88% peak efficiency, under 2 A no-load, UL 458, 10.1 lb No fuse or cable size is published, so the kit uses the 125% rule: 184 A times 1.25 is 230 A, so a 250 A fuse on 1/0 AWG, the pair Renogy specifies for its 2,000 W. source1Buy on Amazon
        Battery monitorRich Solar 500 A battery monitor with shunt (RS-BM500)Rich Solar 500 A battery monitor with shunt (RS-BM500)500 A shunt, 8 to 120 V, ±1% capacity, voltage and current accuracy source1Buy on Amazon
        Battery and inverter cable (if the included cables are too short)WindyNation 1/0 AWG welding and battery cable, 10 ft red and 10 ft blackWindyNation 1/0 AWG welding and battery cable, 10 ft red and 10 ft black1/0 AWG pure copper, 600 V, 105 °C EPDM; 285 A at 105 °C per 33 CFR 183.425 source1Buy on Amazon
        Inverter fuse and holderBlue Sea Systems ANL fuse 250 A (5131) in ANL block (5005)Blue Sea Systems ANL fuse 250 A (5131) in ANL block (5005)250 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 2000 W source1Buy on Amazon
        Bus bars (two)Blue Sea Systems MaxiBus 250 A (2127)Blue Sea Systems MaxiBus 250 A (2127)250 A continuous, 48 V DC, four 5/16 in studs; one positive, one negative source2Buy on Amazon
        Battery disconnect switchBlue Sea Systems m-Series mini on-off switch (6006)Blue Sea Systems m-Series mini on-off switch (6006)300 A continuous, 500 A for 5 min, 48 V DC source1Buy on Amazon
        12 V fuse blockBlue Sea Systems ST Blade fuse block, 12 circuits (5026)Blue Sea Systems ST Blade fuse block, 12 circuits (5026)30 A per circuit, 100 A per block, 32 V DC, negative bus source1Buy on Amazon
        PV string fuseRich Solar In-line fuse holder, 20 A (RS-SC20F)Rich Solar In-line fuse holder, 20 A (RS-SC20F)10, 15, 20 or 30 A options, 1000 V DC, IP67. The MEGA 200 string needs 20 A (11.6 A × 1.56 = 18.1 A) source1Buy on Amazon
        PV disconnect breakerRenogy 1P DC miniature circuit breaker, 32 ARenogy 1P DC miniature circuit breaker, 32 A10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source1Buy on Amazon
        Panel mountsRich Solar Z-brackets with screws, pack of four (RS-ZB4C)Rich Solar Z-brackets with screws, pack of four (RS-ZB4C)Anodized aluminum; one pack per panel, made for the MEGA panels source3Buy on Amazon
        Roof cable entryRich Solar Cable entry housing (RS-C2B)Rich Solar Cable entry housing (RS-C2B)UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source1Buy on Amazon
        PV cable (roof to controller)Rich Solar 10 AWG solar extension cable pair, 20 ft (RS-20102)Rich Solar 10 AWG solar extension cable pair, 20 ft (RS-20102)10 AWG, 1000 V DC, MC4-compatible ends; 20 ft pair covers most roofs source1Buy on Amazon

        Victron + Battle Born

        600 W · 200 Ah · 1,600 W · 15 parts

        Victron controller, monitor and inverter in one app; Battle Born batteries built in Reno. Panels are Renogy, since Victron sells none. Specs are as published by each maker on 2026-10-13; click the source to check.

        RolePartWhy this oneQtyBuy
        Solar panelRenogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source3Buy on Amazon
        MPPT charge controllerVictron Energy SmartSolar MPPT 150/60Victron Energy SmartSolar MPPT 150/6060 A, 150 V max PV, 860 W nominal PV at 12 V, Bluetooth source1Buy on Amazon
        LiFePO4 batteryBattle Born 100 Ah 12 V LiFePO4 (BB10012)Battle Born 100 Ah 12 V LiFePO4 (BB10012)100 Ah, 100 A continuous, 200 A surge for 30 s, 3,000 to 5,000 cycles, cold-charging protection, 31 lb, made in Reno Battle Born's one 12 V size above 100 Ah is the 270 Ah GC3; the kits add 100 Ah units in parallel instead. source2Buy on Amazon
        Pure sine inverterVictron Energy Phoenix Inverter Smart 12/2000, 120 VVictron Energy Phoenix Inverter Smart 12/2000, 120 V2,000 VA: 1,600 W continuous at 25 °C, 4,000 W peak, 92% max efficiency, 8 W no-load, Bluetooth; Victron specifies a 300 A fuse and 70 mm² cable Victron's datasheet lists 350 to 1,000 Ah of battery behind this inverter; two Battle Borns run it, four is Victron's comfort zone. 70 mm² sits between 2/0 and 4/0 AWG, so the kit lists 4/0. source1Buy on Amazon
        Battery monitorVictron Energy SmartShunt 500 AVictron Energy SmartShunt 500 A500 A shunt, 6.5 to 70 V, Bluetooth app shows state of charge source1Buy on Amazon
        Battery and inverter cableWindyNation 4/0 AWG welding and battery cableWindyNation 4/0 AWG welding and battery cable4/0 AWG pure copper, 600 V, 105 °C EPDM; 445 A at 105 °C per 33 CFR 183.425 source1Buy on Amazon
        Inverter fuse and holderBlue Sea Systems Class T fuse 300 A (5119) in Class T block (5502)Blue Sea Systems Class T fuse 300 A (5119) in Class T block (5502)300 A, 125 V DC, 20,000 A interrupt; the fuse Victron specifies for the 12/2000 The cart adds the block; the 300 A fuse itself opens an Amazon search. source1Buy on Amazon
        Bus bars (two)Blue Sea Systems MaxiBus 250 A (2127)Blue Sea Systems MaxiBus 250 A (2127)250 A continuous, 48 V DC, four 5/16 in studs; one positive, one negative source2Buy on Amazon
        Battery disconnect switchBlue Sea Systems m-Series mini on-off switch (6006)Blue Sea Systems m-Series mini on-off switch (6006)300 A continuous, 500 A for 5 min, 48 V DC source1Buy on Amazon
        12 V fuse blockBlue Sea Systems ST Blade fuse block, 12 circuits (5026)Blue Sea Systems ST Blade fuse block, 12 circuits (5026)30 A per circuit, 100 A per block, 32 V DC, negative bus source1Buy on Amazon
        PV string fuseRenogy MC4 in-line fuse holder (15 or 20 A)Renogy MC4 in-line fuse holder (15 or 20 A)10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source1Buy on Amazon
        PV disconnect breakerRenogy 1P DC miniature circuit breaker, 32 ARenogy 1P DC miniature circuit breaker, 32 A10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source1Buy on Amazon
        Panel mountsRenogy Z bracket set of 4Renogy Z bracket set of 4Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source3Buy on Amazon
        Roof cable entryRenogy Double cable entry glandRenogy Double cable entry glandUV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source1Buy on Amazon
        PV cable (roof to controller)Renogy 10 AWG MC4 extension cable pairRenogy 10 AWG MC4 extension cable pair10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source1Buy on Amazon

        Value mix

        600 W · 200 Ah · 2,000 W · 15 parts

        Victron controller and monitor, LiTime battery, Renogy panels and inverter: the lowest price for the same numbers. Specs are as published by each maker on 2026-10-13; click the source to check.

        RolePartWhy this oneQtyBuy
        Solar panelRenogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source3Buy on Amazon
        MPPT charge controllerVictron Energy SmartSolar MPPT 150/60Victron Energy SmartSolar MPPT 150/6060 A, 150 V max PV, 860 W nominal PV at 12 V, Bluetooth source1Buy on Amazon
        LiFePO4 batteryLiTime 12 V 200 Ah Plus LiFePO4200 Ah, 2,560 Wh, 200 A BMS, 4,000 cycles at 100% DoD, 48 lb source1Buy on Amazon
        Pure sine inverterRenogy 2000 W 12 V pure sine wave (P2)Renogy 2000 W 12 V pure sine wave (P2)2,000 W continuous, 4,000 W surge for 1 s, under 2 A no-load, 1/0 AWG 3 ft cables included source1Buy on Amazon
        Battery monitorVictron Energy SmartShunt 500 AVictron Energy SmartShunt 500 A500 A shunt, 6.5 to 70 V, Bluetooth app shows state of charge source1Buy on Amazon
        Battery and inverter cable (if the included cables are too short)WindyNation 1/0 AWG welding and battery cable, 10 ft red and 10 ft blackWindyNation 1/0 AWG welding and battery cable, 10 ft red and 10 ft black1/0 AWG pure copper, 600 V, 105 °C EPDM; 285 A at 105 °C per 33 CFR 183.425 source1Buy on Amazon
        Inverter fuse and holderBlue Sea Systems ANL fuse 250 A (5131) in ANL block (5005)Blue Sea Systems ANL fuse 250 A (5131) in ANL block (5005)250 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 2000 W source1Buy on Amazon
        Bus bars (two)Blue Sea Systems MaxiBus 250 A (2127)Blue Sea Systems MaxiBus 250 A (2127)250 A continuous, 48 V DC, four 5/16 in studs; one positive, one negative source2Buy on Amazon
        Battery disconnect switchBlue Sea Systems m-Series mini on-off switch (6006)Blue Sea Systems m-Series mini on-off switch (6006)300 A continuous, 500 A for 5 min, 48 V DC source1Buy on Amazon
        12 V fuse blockBlue Sea Systems ST Blade fuse block, 12 circuits (5026)Blue Sea Systems ST Blade fuse block, 12 circuits (5026)30 A per circuit, 100 A per block, 32 V DC, negative bus source1Buy on Amazon
        PV string fuseRenogy MC4 in-line fuse holder (15 or 20 A)Renogy MC4 in-line fuse holder (15 or 20 A)10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source1Buy on Amazon
        PV disconnect breakerRenogy 1P DC miniature circuit breaker, 32 ARenogy 1P DC miniature circuit breaker, 32 A10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source1Buy on Amazon
        Panel mountsRenogy Z bracket set of 4Renogy Z bracket set of 4Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source3Buy on Amazon
        Roof cable entryRenogy Double cable entry glandRenogy Double cable entry glandUV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source1Buy on Amazon
        PV cable (roof to controller)Renogy 10 AWG MC4 extension cable pairRenogy 10 AWG MC4 extension cable pair10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source1Buy on Amazon

        Off-grid Four 200 W panels, 400 Ah of LiFePO4, a 60 A MPPT, a 3,000 W class inverter and an alternator charger for cloudy weeks.

        Renogy

        800 W · 400 Ah · 3,000 W · 17 parts

        One maker for panels, controller, battery, inverter and monitor. Specs are as published by each maker on 2026-10-13; click the source to check.

        RolePartWhy this oneQtyBuy
        Solar panelRenogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source4Buy on Amazon
        MPPT charge controllerRenogy Rover 60 A MPPT (RNG-CTRL-RVR60)Renogy Rover 60 A MPPT (RNG-CTRL-RVR60)60 A, 140 V max PV input, 800 W of panels at 12 V; Bluetooth with the BT-2 module source1Buy on Amazon
        LiFePO4 batteryRenogy 12 V 100 Ah Pro, Bluetooth and self-heating (RBT12100LFP-BT)Renogy 12 V 100 Ah Pro, Bluetooth and self-heating (RBT12100LFP-BT)100 Ah, 100 A BMS, 5,000 cycles at 80% DoD, self-heating below 41 °F, 26.9 lb source4Buy on Amazon
        Pure sine inverterRenogy 3000 W 12 V pure sine wave (P2)Renogy 3000 W 12 V pure sine wave (P2)3,000 W continuous, 6,000 W surge for 1 s, under 2.5 A no-load, 4/0 AWG recommended source1Buy on Amazon
        Battery monitorRenogy 500 A battery monitor with shunt (RBM500)Renogy 500 A battery monitor with shunt (RBM500)500 A shunt, 10 to 120 V, ±1% capacity accuracy, backlit display on a 20 ft lead source1Buy on Amazon
        Battery and inverter cableWindyNation 4/0 AWG welding and battery cableWindyNation 4/0 AWG welding and battery cable4/0 AWG pure copper, 600 V, 105 °C EPDM; 445 A at 105 °C per 33 CFR 183.425 source1Buy on Amazon
        Inverter fuse and holderBlue Sea Systems Class T fuse 400 A (5121) in Class T block (5502)Blue Sea Systems Class T fuse 400 A (5121) in Class T block (5502)400 A, 125 V DC, 20,000 A interrupt; the fuse Renogy specifies for the 3000 W source1Buy on Amazon
        Bus bars (two)Blue Sea Systems PowerBar 1000 A (1991)Blue Sea Systems PowerBar 1000 A (1991)1,000 A continuous, 150 V, twelve 3/8 in studs; one positive, one negative source2Buy on Amazon
        Battery disconnect switchBlue Sea Systems e-Series on-off switch (9003e)Blue Sea Systems e-Series on-off switch (9003e)350 A continuous, 600 A for 5 min, 48 V DC source1Buy on Amazon
        12 V fuse blockBlue Sea Systems ST Blade fuse block, 12 circuits (5026)Blue Sea Systems ST Blade fuse block, 12 circuits (5026)30 A per circuit, 100 A per block, 32 V DC, negative bus source1Buy on Amazon
        PV string fuseRenogy MC4 in-line fuse holder (15 or 20 A)Renogy MC4 in-line fuse holder (15 or 20 A)10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source2Buy on Amazon
        PV disconnect breakerRenogy 1P DC miniature circuit breaker, 32 ARenogy 1P DC miniature circuit breaker, 32 A10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source1Buy on Amazon
        Panel mountsRenogy Z bracket set of 4Renogy Z bracket set of 4Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source4Buy on Amazon
        Roof cable entryRenogy Double cable entry glandRenogy Double cable entry glandUV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source1Buy on Amazon
        PV cable (roof to controller)Renogy 10 AWG MC4 extension cable pairRenogy 10 AWG MC4 extension cable pair10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source1Buy on Amazon
        MC4 branch connectorsRenogy Y branch pair, 2 to 1Renogy Y branch pair, 2 to 130 A, 1500 V DC, IP67; only if you wire panels in parallel source1Buy on Amazon
        DC-DC alternator charger (optional) (optional)Renogy 12 V 50 A DC-DC on-board charger with MPPT (DCC50S)Renogy 12 V 50 A DC-DC on-board charger with MPPT (DCC50S)50 A from the alternator while driving; also takes up to 660 W of solar at 50 V source1Buy on Amazon

        Rich Solar

        800 W · 400 Ah · 3,000 W · 17 parts

        One maker for panels, controller, battery, inverter, monitor and roof hardware. Specs are as published by each maker on 2026-10-13; click the source to check.

        RolePartWhy this oneQtyBuy
        Solar panelRich Solar MEGA 200 (RS-M200)Rich Solar MEGA 200 (RS-M200)200 W, Voc 21.8 V, Vmp 18.4 V, Isc 11.6 A, 58.7 × 26.8 in, 24 lb source4Buy on Amazon
        MPPT charge controllerRich Solar BRAVO 60 MPPT (RS-MPPT60P)Rich Solar BRAVO 60 MPPT (RS-MPPT60P)60 A, 100 V max PV open-circuit voltage, 900 W of panels recommended at 12 V, Bluetooth The Off-grid kit wires its four MEGA 200 as two strings of two (about 50 V cold). Four in one string would be about 99 V on a −10 °C morning, too close to the 100 V limit. source1Buy on Amazon
        LiFePO4 batteryRich Solar ALPHA 1 12 V 100 Ah, Bluetooth and internal heater (RS-B121S)Rich Solar ALPHA 1 12 V 100 Ah, Bluetooth and internal heater (RS-B121S)100 Ah, 1,280 Wh, 100 A continuous discharge, 5,000+ cycles at 80% DoD, 100 W heater, 24 lb The bigger kits run several in parallel: Rich Solar's ALPHA 2 200 Ah page lists only 100 A of discharge, which cannot feed a 2,000 W inverter on its own. source4Buy on Amazon
        Pure sine inverterRich Solar NOVA PURE 3K 12 V (RS-V3P12)Rich Solar NOVA PURE 3K 12 V (RS-V3P12)3,000 W continuous, 6,000 W surge, over 88% peak efficiency, under 2 A no-load, UL 458, 12.1 lb No fuse or cable size is published, so the kit uses the 125% rule: 276 A times 1.25 is 345 A, so a 400 A Class T on 4/0 AWG, the pair Renogy specifies for its 3,000 W. source1Buy on Amazon
        Battery monitorRich Solar 500 A battery monitor with shunt (RS-BM500)Rich Solar 500 A battery monitor with shunt (RS-BM500)500 A shunt, 8 to 120 V, ±1% capacity, voltage and current accuracy source1Buy on Amazon
        Battery and inverter cableWindyNation 4/0 AWG welding and battery cableWindyNation 4/0 AWG welding and battery cable4/0 AWG pure copper, 600 V, 105 °C EPDM; 445 A at 105 °C per 33 CFR 183.425 source1Buy on Amazon
        Inverter fuse and holderBlue Sea Systems Class T fuse 400 A (5121) in Class T block (5502)Blue Sea Systems Class T fuse 400 A (5121) in Class T block (5502)400 A, 125 V DC, 20,000 A interrupt; the fuse Renogy specifies for the 3000 W source1Buy on Amazon
        Bus bars (two)Blue Sea Systems PowerBar 1000 A (1991)Blue Sea Systems PowerBar 1000 A (1991)1,000 A continuous, 150 V, twelve 3/8 in studs; one positive, one negative source2Buy on Amazon
        Battery disconnect switchBlue Sea Systems e-Series on-off switch (9003e)Blue Sea Systems e-Series on-off switch (9003e)350 A continuous, 600 A for 5 min, 48 V DC source1Buy on Amazon
        12 V fuse blockBlue Sea Systems ST Blade fuse block, 12 circuits (5026)Blue Sea Systems ST Blade fuse block, 12 circuits (5026)30 A per circuit, 100 A per block, 32 V DC, negative bus source1Buy on Amazon
        PV string fuseRich Solar In-line fuse holder, 20 A (RS-SC20F)Rich Solar In-line fuse holder, 20 A (RS-SC20F)10, 15, 20 or 30 A options, 1000 V DC, IP67. The MEGA 200 string needs 20 A (11.6 A × 1.56 = 18.1 A) source2Buy on Amazon
        PV disconnect breakerRenogy 1P DC miniature circuit breaker, 32 ARenogy 1P DC miniature circuit breaker, 32 A10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source1Buy on Amazon
        Panel mountsRich Solar Z-brackets with screws, pack of four (RS-ZB4C)Rich Solar Z-brackets with screws, pack of four (RS-ZB4C)Anodized aluminum; one pack per panel, made for the MEGA panels source4Buy on Amazon
        Roof cable entryRich Solar Cable entry housing (RS-C2B)Rich Solar Cable entry housing (RS-C2B)UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source1Buy on Amazon
        PV cable (roof to controller)Rich Solar 10 AWG solar extension cable pair, 20 ft (RS-20102)Rich Solar 10 AWG solar extension cable pair, 20 ft (RS-20102)10 AWG, 1000 V DC, MC4-compatible ends; 20 ft pair covers most roofs source1Buy on Amazon
        MC4 branch connectorsRenogy Y branch pair, 2 to 1Renogy Y branch pair, 2 to 130 A, 1500 V DC, IP67; only if you wire panels in parallel source1Buy on Amazon
        DC-DC alternator charger (optional) (optional)Rich Solar 12 V 40 A DC-DC battery charger (RS-DC40)Rich Solar 12 V 40 A DC-DC battery charger (RS-DC40)40 A from the alternator while driving, 10 to 16 V input; manual calls for a 60 A input fuse, 50 A output fuse, 6 AWG in and 8 AWG out source1Buy on Amazon

        Victron + Battle Born

        800 W · 400 Ah · 2,400 W · 17 parts

        Victron controller, monitor and inverter in one app; Battle Born batteries built in Reno. Panels are Renogy, since Victron sells none. Specs are as published by each maker on 2026-10-13; click the source to check.

        RolePartWhy this oneQtyBuy
        Solar panelRenogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC)200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source4Buy on Amazon
        MPPT charge controllerVictron Energy SmartSolar MPPT 150/60Victron Energy SmartSolar MPPT 150/6060 A, 150 V max PV, 860 W nominal PV at 12 V, Bluetooth source1Buy on Amazon
        LiFePO4 batteryBattle Born 100 Ah 12 V LiFePO4 (BB10012)Battle Born 100 Ah 12 V LiFePO4 (BB10012)100 Ah, 100 A continuous, 200 A surge for 30 s, 3,000 to 5,000 cycles, cold-charging protection, 31 lb, made in Reno Battle Born's one 12 V size above 100 Ah is the 270 Ah GC3; the kits add 100 Ah units in parallel instead. source4Buy on Amazon
        Pure sine inverterVictron Energy Phoenix Inverter Smart 12/3000, 120 VVictron Energy Phoenix Inverter Smart 12/3000, 120 V3,000 VA: 2,400 W continuous at 25 °C, 6,000 W peak, 93% max efficiency, 12 W no-load, Bluetooth; Victron specifies a 400 A fuse and 90 mm² cable Victron lists 400 to 1,200 Ah of battery for it; the kit's four Battle Borns are the floor. source1Buy on Amazon
        Battery monitorVictron Energy SmartShunt 500 AVictron Energy SmartShunt 500 A500 A shunt, 6.5 to 70 V, Bluetooth app shows state of charge source1Buy on Amazon
        Battery and inverter cableWindyNation 4/0 AWG welding and battery cableWindyNation 4/0 AWG welding and battery cable4/0 AWG pure copper, 600 V, 105 °C EPDM; 445 A at 105 °C per 33 CFR 183.425 source1Buy on Amazon
        Inverter fuse and holderBlue Sea Systems Class T fuse 400 A (5121) in Class T block (5502)Blue Sea Systems Class T fuse 400 A (5121) in Class T block (5502)400 A, 125 V DC, 20,000 A interrupt; the fuse Renogy specifies for the 3000 W source1Buy on Amazon
        Bus bars (two)Blue Sea Systems PowerBar 1000 A (1991)Blue Sea Systems PowerBar 1000 A (1991)1,000 A continuous, 150 V, twelve 3/8 in studs; one positive, one negative source2Buy on Amazon
        Battery disconnect switchBlue Sea Systems e-Series on-off switch (9003e)Blue Sea Systems e-Series on-off switch (9003e)350 A continuous, 600 A for 5 min, 48 V DC source1Buy on Amazon
        12 V fuse blockBlue Sea Systems ST Blade fuse block, 12 circuits (5026)Blue Sea Systems ST Blade fuse block, 12 circuits (5026)30 A per circuit, 100 A per block, 32 V DC, negative bus source1Buy on Amazon
        PV string fuseRenogy MC4 in-line fuse holder (15 or 20 A)Renogy MC4 in-line fuse holder (15 or 20 A)10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source2Buy on Amazon
        PV disconnect breakerRenogy 1P DC miniature circuit breaker, 32 ARenogy 1P DC miniature circuit breaker, 32 A10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source1Buy on Amazon
        Panel mountsRenogy Z bracket set of 4Renogy Z bracket set of 4Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source4Buy on Amazon
        Roof cable entryRenogy Double cable entry glandRenogy Double cable entry glandUV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source1Buy on Amazon
        PV cable (roof to controller)Renogy 10 AWG MC4 extension cable pairRenogy 10 AWG MC4 extension cable pair10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source1Buy on Amazon
        MC4 branch connectorsRenogy Y branch pair, 2 to 1Renogy Y branch pair, 2 to 130 A, 1500 V DC, IP67; only if you wire panels in parallel source1Buy on Amazon
        DC-DC alternator charger (optional) (optional)Victron Energy Orion XS 12/12-50 AVictron Energy Orion XS 12/12-50 A50 A from the alternator while driving, 98.5% efficient; the rainy-week backstop source1Buy on Amazon

        Value mix

        800 W · 400 Ah · 3,000 W · 16 parts

        Victron controller and monitor, LiTime battery, Renogy panels and inverter: the lowest price for the same numbers. Specs are as published by each maker on 2026-10-13; click the source to check.

        RolePartWhy this oneQtyBuy
        Solar panelRich Solar MEGA 200 (RS-M200)Rich Solar MEGA 200 (RS-M200)200 W, Voc 21.8 V, Vmp 18.4 V, Isc 11.6 A, 58.7 × 26.8 in, 24 lb source4Buy on Amazon
        MPPT charge controllerVictron Energy SmartSolar MPPT 150/60Victron Energy SmartSolar MPPT 150/6060 A, 150 V max PV, 860 W nominal PV at 12 V, Bluetooth source1Buy on Amazon
        LiFePO4 batteryLiTime 12 V 200 Ah Plus LiFePO4200 Ah, 2,560 Wh, 200 A BMS, 4,000 cycles at 100% DoD, 48 lb source2Buy on Amazon
        Pure sine inverterRenogy 3000 W 12 V pure sine wave (P2)Renogy 3000 W 12 V pure sine wave (P2)3,000 W continuous, 6,000 W surge for 1 s, under 2.5 A no-load, 4/0 AWG recommended source1Buy on Amazon
        Battery monitorVictron Energy SmartShunt 500 AVictron Energy SmartShunt 500 A500 A shunt, 6.5 to 70 V, Bluetooth app shows state of charge source1Buy on Amazon
        Battery and inverter cableWindyNation 4/0 AWG welding and battery cableWindyNation 4/0 AWG welding and battery cable4/0 AWG pure copper, 600 V, 105 °C EPDM; 445 A at 105 °C per 33 CFR 183.425 source1Buy on Amazon
        Inverter fuse and holderBlue Sea Systems Class T fuse 400 A (5121) in Class T block (5502)Blue Sea Systems Class T fuse 400 A (5121) in Class T block (5502)400 A, 125 V DC, 20,000 A interrupt; the fuse Renogy specifies for the 3000 W source1Buy on Amazon
        Bus bars (two)Blue Sea Systems PowerBar 1000 A (1991)Blue Sea Systems PowerBar 1000 A (1991)1,000 A continuous, 150 V, twelve 3/8 in studs; one positive, one negative source2Buy on Amazon
        Battery disconnect switchBlue Sea Systems e-Series on-off switch (9003e)Blue Sea Systems e-Series on-off switch (9003e)350 A continuous, 600 A for 5 min, 48 V DC source1Buy on Amazon
        12 V fuse blockBlue Sea Systems ST Blade fuse block, 12 circuits (5026)Blue Sea Systems ST Blade fuse block, 12 circuits (5026)30 A per circuit, 100 A per block, 32 V DC, negative bus source1Buy on Amazon
        PV string fuseRenogy MC4 in-line fuse holder (15 or 20 A)Renogy MC4 in-line fuse holder (15 or 20 A)10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source1Buy on Amazon
        PV disconnect breakerRenogy 1P DC miniature circuit breaker, 32 ARenogy 1P DC miniature circuit breaker, 32 A10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source1Buy on Amazon
        Panel mountsRenogy Z bracket set of 4Renogy Z bracket set of 4Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source4Buy on Amazon
        Roof cable entryRenogy Double cable entry glandRenogy Double cable entry glandUV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source1Buy on Amazon
        PV cable (roof to controller)Renogy 10 AWG MC4 extension cable pairRenogy 10 AWG MC4 extension cable pair10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source1Buy on Amazon
        DC-DC alternator charger (optional) (optional)Victron Energy Orion XS 12/12-50 AVictron Energy Orion XS 12/12-50 A50 A from the alternator while driving, 98.5% efficient; the rainy-week backstop source1Buy on Amazon
        Wiring and protection

        How it goes together, and why each number is what it is

        Install order, string voltage and fuses

        Install order

        1. Mount the panels with Z brackets and lap sealant. Wire each string in series: positive of one panel to negative of the next, so the volts add. Most kits are one string with one pair of 10 AWG leads; the Off-grid kits on Renogy panels and the Rich Solar Off-grid kit are two strings of two, each with its own fuse, joined in parallel (positive to positive, negative to negative) with branch connectors after the fuses.
        2. Fuse the string with an MC4 in-line fuse at 156% of the panel's short-circuit current (NEC 690.8), then bring the leads through the roof gland to a DC breaker you can switch off before touching anything.
        3. Connect battery before panels. The controller needs to see the battery first; Victron's manual requires the PV voltage to be at least 5 V above the battery to start and below the controller's limit on the coldest morning.
        4. Bus bars take the load. Battery to a disconnect switch, then the main fuse within 7 inches of the battery terminal, then the positive bus bar. Controller, inverter and the 12 V fuse block all land on the bus bars, never stacked on one battery post.
        5. Inverter on its own fuse and cable as its manual specifies: 150 A and 4 AWG for 1,000 W, 250 A and 1/0 AWG for 2,000 W, 400 A and 4/0 AWG for 3,000 W. Keep the run under 3 ft.
        6. Shunt on the negative. Every negative goes to the battery through the SmartShunt so the app shows a true state of charge.

        String voltage on a cold morning

        Kit and panelIn seriesVoc at 25 °CVoc at −10 °CController limit
        Weekender (Renogy), RSP200D G3123.0 V25.3 V100 V
        Weekender (Renogy), RSP200DC N-type137.4 V41.1 V100 V
        Full-timer (Renogy), RSP200D G3369.0 V75.8 V140 V
        Full-timer (Renogy), RSP200DC N-type3112.3 V123.3 V140 V
        Off-grid (Renogy), RSP200D G32 × 2 strings46.0 V50.5 V140 V
        Off-grid (Renogy), RSP200DC N-type2 × 2 strings74.9 V82.2 V140 V
        Weekender (Rich Solar), MEGA 200121.8 V24.9 V100 V
        Full-timer (Rich Solar), MEGA 200365.4 V74.6 V100 V
        Off-grid (Rich Solar), MEGA 2002 × 2 strings43.6 V49.7 V100 V
        Weekender (Victron + Battle Born), RSP200D G3123.0 V25.3 V100 V
        Weekender (Victron + Battle Born), RSP200DC N-type137.4 V41.1 V100 V
        Full-timer (Victron + Battle Born), RSP200D G3369.0 V75.8 V150 V
        Full-timer (Victron + Battle Born), RSP200DC N-type3112.3 V123.3 V150 V
        Off-grid (Victron + Battle Born), RSP200D G32 × 2 strings46.0 V50.5 V150 V
        Off-grid (Victron + Battle Born), RSP200DC N-type2 × 2 strings74.9 V82.2 V150 V
        Weekender (Value mix), RSP200D G3123.0 V25.3 V100 V
        Weekender (Value mix), RSP200DC N-type137.4 V41.1 V100 V
        Full-timer (Value mix), RSP200D G3369.0 V75.8 V150 V
        Full-timer (Value mix), RSP200DC N-type3112.3 V123.3 V150 V
        Off-grid (Value mix), MEGA 200487.2 V99.4 V150 V

        Voc rises 0.28% per degree below 25 °C (Renogy datasheet). Renogy sells two very different panels under one 200 W name: the G3 (23 V) and the N-type RSP200DC (37.44 V). Three N-types in series is 123 V cold, which is why the Full-timer kits use a 140 or 150 V controller rather than a 100 V one, and four would be 164 V, which is why the Off-grid kits on Renogy panels run two strings of two. Rich Solar does not publish the MEGA 200's coefficient, so its rows use the NEC 690.7 table factor of 1.14; four of them in one string would be 99 V on a 100 V controller, too close, so the Rich Solar Off-grid kit also runs two strings of two.

        Fuses in each kit

        KitString fuseInverter currentInverter fuseCable
        Weekender (Renogy)20 A for the RSP200D G3, 15 A for the RSP200DC N-type
        11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A
        92 A150 A (maker's figure; 125% rule gives 125 A)4 AWG, 160 A at 105 °C
        Full-timer (Renogy)20 A for the RSP200D G3, 15 A for the RSP200DC N-type
        11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A
        184 A250 A1/0 AWG, 285 A at 105 °C
        Off-grid (Renogy)20 A for the RSP200D G3, 15 A for the RSP200DC N-type
        11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A
        276 A400 A4/0 AWG, 445 A at 105 °C
        Weekender (Rich Solar)20 A
        11.6 A × 1.56 = 18.1 A
        92 A150 A (maker's figure; 125% rule gives 125 A)4 AWG, 160 A at 105 °C
        Full-timer (Rich Solar)20 A
        11.6 A × 1.56 = 18.1 A
        184 A250 A1/0 AWG, 285 A at 105 °C
        Off-grid (Rich Solar)20 A
        11.6 A × 1.56 = 18.1 A
        276 A400 A4/0 AWG, 445 A at 105 °C
        Weekender (Victron + Battle Born)20 A for the RSP200D G3, 15 A for the RSP200DC N-type
        11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A
        92 A150 A (maker's figure; 125% rule gives 125 A)1/0 AWG, 285 A at 105 °C
        Full-timer (Victron + Battle Born)20 A for the RSP200D G3, 15 A for the RSP200DC N-type
        11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A
        147 A300 A (maker's figure; 125% rule gives 200 A)4/0 AWG, 445 A at 105 °C
        Off-grid (Victron + Battle Born)20 A for the RSP200D G3, 15 A for the RSP200DC N-type
        11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A
        221 A400 A (maker's figure; 125% rule gives 300 A)4/0 AWG, 445 A at 105 °C
        Weekender (Value mix)20 A for the RSP200D G3, 15 A for the RSP200DC N-type
        11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A
        92 A150 A (maker's figure; 125% rule gives 125 A)4 AWG, 160 A at 105 °C
        Full-timer (Value mix)20 A for the RSP200D G3, 15 A for the RSP200DC N-type
        11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A
        184 A250 A1/0 AWG, 285 A at 105 °C
        Off-grid (Value mix)20 A
        11.6 A × 1.56 = 18.1 A
        276 A400 A4/0 AWG, 445 A at 105 °C

        Wire gauge for 12 V runs (3% drop, copper, 105 °C insulation)

        Load5 ft one way10 ft one way15 ft one way25 ft one way
        10 A12 AWG12 AWG10 AWG8 AWG
        20 A12 AWG8 AWG6 AWG4 AWG
        30 A10 AWG6 AWG6 AWG2 AWG
        50 A8 AWG4 AWG2 AWG1/0 AWG
        100 A4 AWG2 AWG1/0 AWG4/0 AWG
        150 A2 AWG1/0 AWG2/0 AWG4/0 AWG

        Ampacity from 33 CFR 183.425 Table 5; resistance from Blue Sea Systems' catalog; 3% drop is Blue Sea's rule for critical circuits. Length is one way; the arithmetic uses the round trip.

        The rules, with their sources

        • 12.8 V and 1,280 Wh per 100 Ah. LiTime's own spec for its 100 Ah LiFePO4. LiTime
        • 80% usable, LiFePO4 only. LiTime rates 4,000 cycles at 100% and 6,000 at 80%; Battle Born allows 100%. We plan at 80% for a long life and a reserve, and we size for lithium only: lead-acid gives up half its capacity and most of its life for the same money. LiTime, Battle Born
        • 85% inverter efficiency. Renogy's P2 manual states over 85% at full load; Victron's Phoenix tops out at 91 to 92%. We use the floor. Renogy, Victron
        • Battery: Wh × days of autonomy ÷ volts ÷ usable depth. The IEEE 1013 and Sandia stand-alone PV form. We use no cold derate: LiFePO4 is rated at 25 °C and its BMS stops charging below about 0 °C, so plan on less in a freezing cabin. Sandia handbook, Victron LFP datasheet
        • Days of autonomy. AS/NZS 4509.2 plans 2 days with an automatic generator, 2 to 3 with a manual one, 4 to 5 with none; IEEE 1562 plans 5 to 7 for non-critical loads. The buttons offer 1 to 3 because an RV has an engine and shore power behind it; pick more for a week in one place. GSES on AS/NZS 4509.2, SunWize on IEEE 1562
        • Panels: Wh × 1.2 ÷ sun hours ÷ 0.86 ÷ 0.92. IEEE 1562's array-to-load ratio is 1.1 to 1.2 for non-critical loads and 1.3 to 1.4 for critical ones; we take 1.2. PVWatts v5's default system losses are 14% (soiling 2, shading 3, mismatch 2, wiring 2, connections 0.5, light-induced degradation 1.5, nameplate 1, availability 3). Victron rates LiFePO4 round-trip efficiency at 92%. Together that is 0.79 of nameplate reaching the battery. IEEE 1562, PVWatts losses, Victron
        • Battery BMS must carry the inverter. Every LiFePO4 has a BMS with a continuous discharge limit (100 A on a 100 Ah Renogy Pro, Battle Born or LiTime; 200 A on a 200 Ah). The bank's limit, BMS amps × batteries in parallel, must cover the inverter's full-load draw, W ÷ 12.8 V ÷ 0.85: 184 A for 2,000 W, 276 A for 3,000 W. That is why the Full-timer runs two 100 Ah in parallel and the Off-grid four, and why one 400 Ah with a 250 A BMS is not in any kit. Renogy, Battle Born
        • Inverter: 120 V loads that run together × 1.25. The NEC continuous-load rule (210.20, 215.2): equipment serving a continuous load is rated at 125% of it. Motor starts are checked against the inverter's 2× surge rating. NEC
        • Peak sun hours by region. NREL PVWatts and NSRDB figures as published by city, state and university bodies; December values from the same reports. Size for the worst month you camp in. All five sources
        • MPPT amps = panel W ÷ 14.4 V. Victron's nominal PV power ratings (700 W on the 50 A) are exactly that arithmetic; a controller clips extra panel power safely. Victron
        • Cold Voc. The controller's PV limit must exceed the string's open-circuit voltage at the coldest morning; Renogy's coefficient is −0.28% per °C; NEC Table 690.7 gives 1.14 for −10 °C. Victron manual, Renogy datasheet, NEC 690.7
        • String fuse at 156% of Isc. NEC 690.8: 125% for max current, 125% again for continuous duty. EC&M on NEC 690.8
        • Inverter fuse and cable. The maker's manual rules; Renogy specifies 150, 250 and 400 A with 4, 1/0 and 4/0 AWG. The 125% continuous-load rule lands on the same sizes. Renogy P2 manual
        • Ampacity and 3% drop. 33 CFR 183.425 Table 5 for how much a wire may carry; Blue Sea Systems for the 3% rule and resistance per 1,000 ft. 33 CFR 183.425, Blue Sea
        • Alternator charging: 640 Wh an hour of driving. Victron's Orion XS 12/12-50 delivers 50 A; at 12.8 V that is 640 Wh an hour. The charger tapers as the battery fills, so we cap it at 8 h a day. Victron technical data
        • Month-by-month sun from your ZIP. NREL's PVWatts v8 model, flat panel, with the hourly sun reported as peak sun hours; the 14% losses, battery efficiency and array-to-load ratio above are applied after. The five regions are the fallback. PVWatts
        • Roof fit. Panels laid out at their datasheet size (Renogy G3 58.7 × 27.5 in, RSP200DC 49.7 × 30.1 in, Rich Solar 58.7 × 26.8 in) with 2 in between, both orientations tried. The rig presets are rough clear-space figures, not maker numbers.
        • MPPT over PWM. Victron's white paper measured PWM at 19% less harvest at 25 °C, worse when cold or shaded. Victron white paper

        What we could not source from a maker and left out: an induction cooktop's draw, the 12 V heating element of an absorption fridge (dealer figure only, and nobody should run one on 12 V), rooftop AC start-up current, and a manufacturer's number for the flat-versus-tilted penalty. The 0.75 derate, the 1.25 inverter headroom and every "hours a day" are planning conventions, labelled as such.

        Sources

        Every page we read, checked 2026-10-13

        66 sources

        1. Portable fridge: Dometic CFX3 55 (12 V, 53 L) (14 W): www.dometic.com/en-ae/professional/product/dometic-cfx3-55-9600025319
        2. Portable fridge: Dometic CFX3 35 (12 V, 36 L) (13 W): www.dometic.com/en-ae/professional/product/dometic-cfx3-35-9600025317
        3. Portable fridge: Dometic CFX3 75DZ, both zones as fridge (18 W): www.dometic.com/en-ae/product/dometic-cfx3-75dz-9600025321
        4. Portable fridge: Dometic CFX3 95DZ, both zones as fridge (23 W): www.dometic.com/en-ae/professional/product/dometic-cfx3-95dz-960002532…
        5. Portable fridge: ICECO VL45 (12 V, 45 L) (14.5 W): icecofreezer.com/products/iceco-vl45-portable-refrigerator-freezer
        6. Portable fridge: Galanz 9.8 cu ft residential top-freezer (120 V) (33.3 W): www.energystar.gov/productfinder/product/certified-residential-refrige…
        7. LED lights: Thin-Lite LED186P on low (per fixture) (4.32 W): backwoodssolar.com/product/thin-lite-led186p-48-led-fixture/
        8. LED lights: HitLights 12 V COB LED strip (per foot) (3.048 W): hitlights.com/products/premium-12v-cob-led-strip-light-single-color-ul…
        9. Water pump: SHURflo 4008 Revolution 3.0 GPM (64 W): defender.com/assets/pdf/shurflo/pds-4008-101-x65.pdf
        10. Water pump: SHURflo 4048 High Flow 4.0 GPM (at its maximum draw) (128 W): www.pentair.com/en-us/products/residential/water-supply-disposal/recre…
        11. Phones: Phone on a 20 W USB-C charger (20 W): www.apple.com/shop/product/MHJA3AM/A/20w-usb-c-power-adapter
        12. Built-in fridge: Dometic DMC4101 10 cu ft (12 V) (156 W): www.dometic.com/en-us/us/products/food-and-beverage/refrigerators/rv-r…
        13. Water heater: Truma AquaGo Comfort (32 W): www.truma.com/us/boondocking-with-truma-aquago/
        14. Water heater: Girard GSWH-2 (38 W): www.lippert.com/girard-gswh-2-water-heater-2gwham-2022107534
        15. Roof vent fan: MaxxAir MaxxFan Deluxe on low (18 W): nomadicsupply.com/maxxair-maxxfan-deluxe-camper-roof-vent-fan-white-05…
        16. Furnace blower: Suburban NT-16 / NT-20 (16,000 to 20,000 BTU) (36 W): atctrailers.com/wp-content/uploads/2025/04/Suburban_Service_Manual.pdf…
        17. CPAP: ResMed AirSense 10, device only (7 W): document.resmed.com/documents/products/machine/air10-lumis-series/Powe…
        18. CPAP: ResMed AirSense 11 with humidifier and heated tube (56.1 W): document.resmed.com/documents/products/machine/airsense-11/user-guide/…
        19. Cabin fan: Caframo Sirocco II on low (1.5 W): ecofan.caframobrands.com/7010cawbx.html
        20. Hair dryer: Conair 247VHN 1875 W (1875 W): www.conair.com/powerful-drying-%26-styling-hair-dryer/247VHN.html?lang…
        21. Laptop: MacBook Air (30 W adapter) (30 W): support.apple.com/guide/macbook-air/apd3a37305b7/2023/mac/14
        22. Laptop: MacBook Pro 14-inch (96 W adapter) (96 W): www.apple.com/shop/product/MW2L3AM/A/70w-usb-c-power-adapter
        23. Starlink: Starlink Mini (12 V direct) (30 W): starlink.com/public-files/specification_sheet_mini_x.pdf
        24. Starlink: Starlink Standard (through the inverter) (87 W): starlink.com/public-files/specification_sheet_standard.pdf
        25. Cell router: Peplink MAX BR1 Pro 5G (12 V direct) (8 W): download.peplink.com/resources/br1_pro_5g_datasheet.pdf
        26. TV: Samsung 32-inch UN32M4500 (48 W): www.shi.com/product/34933195/Samsung-UN32M4500BF-32-inch-Diagonal-Clas…
        27. TV: Sansui 43-inch LE-43KA1 4K (45.14 W): www.energystar.gov/productfinder/product/certified-televisions/details…
        28. TV: Samsung 43-inch QN90D Neo QLED (63.4 W): www.energystar.gov/productfinder/product/certified-televisions/details…
        29. Microwave: Furrion 0.9 cu ft RV microwave (1350 W): furrion.com/products/0-9-cu-ft-solo-microwave
        30. Induction cooktop: Duxtop 9100MC 1800 W (1800 W): www.thesecura.com/product/duxtop-1800w-portable-induction-cooktop-coun…
        31. Induction cooktop: NuWave PIC Flex Pro 1400 W (1400 W): www.nuwavenow.com/products/nuwave-pic-flex-pro-induction-cooktop
        32. Pressure cooker: Instant Pot Duo 6 qt (1000 W): instantpot.com/collections/ip-6qt/products/instant-pot-duo-6qt-multi-u…
        33. Air fryer: COSORI Pro 5.8 qt (CS358-AF) (1700 W): cosori.com/cdn/shop/files/D3_01.08_M1_CS358-AF_2021-11-01_PRINT_US_en.…
        34. Rooftop AC: Dometic Brisk II 13,500 BTU (1670 W): dometic.com/en-us/us/products/climate/air-conditioners/rv-air-conditio…
        35. Rooftop AC: Dometic Penguin II 13,500 BTU (low profile) (1731 W): dometic.com/en-us/us/products/climate/air-conditioners/rv-air-conditio…
        36. Rooftop AC: Furrion Chill HE 13,500 BTU (1450 W): furrion.com/products/13-5k-he-rooftop-unit-for-furrion-chill-air-condi…
        37. Rooftop AC: Furrion Chill HE 15,000 BTU (1720 W): www.lippert.com/furrion-chill-he-rv-roof-air-conditioner-r32-15k-btu-w…
        38. Space heater: Lasko 754200 on high (1500 W): lasko.com/products/lasko-1500w-electric-ceramic-space-heater-with-adju…
        39. LiTime 12 V 100 Ah LiFePO4 spec (12.8 V nominal, 1,280 Wh, cycle life by depth of discharge): www.litime.com/products/litime-12v-100ah-lifepo4-lithium-battery-built…
        40. Battle Born BB10012 cut sheet (100% DoD, charge voltages): battlebornbatteries.com/wp-content/uploads/2020/06/BB10012-Cut-Sheet-1…
        41. Battle Born, how much solar per 100 Ah: battlebornbatteries.com/blogs/articles/how-much-solar-do-i-need-for-my…
        42. Renogy battery bank sizing guide (days of autonomy): www.renogy.com/blogs/buyers-guide/how-to-size-your-battery-bank-to-ext…
        43. Renogy P2 inverter manual (surge, efficiency, battery fuse and cable table): ca.renogy.com/content/manual/INVT-P2-Manual.pdf
        44. Renogy RSP100D-BK panel datasheet (Voc temperature coefficient, series fuse): eu.renogy.com/content/RSP100D-BK-G2%20Datasheet.pdf
        45. Renogy RSP200D G3 panel datasheet (Voc 23 V, Isc 11.05 A, 20 A series fuse): ca.renogy.com/content/Datasheet/RSP200D-G3%20Datasheet.pdf
        46. Renogy 16BB N-type 200 W panel, RSP200DC (Voc 37.44 V, Isc 6.85 A, 15 A series fuse): fr.renogy.com/en/products/renogy-16bb-n-type-200-watt-24v-solar-panel
        47. Rich Solar MEGA 200 panel page: richsolar.com/products/200-watt-solar-panel
        48. Renogy Rover 40 A MPPT spec (100 V PV limit, 520 W at 12 V): www.renogy.com/rover-40-amp-mppt-solar-charge-controller/
        49. Victron SmartSolar 100/30 and 100/50 datasheet (rated current, nominal PV power, 100 V limit): www.victronenergy.com/upload/documents/Datasheet-SmartSolar-charge-con…
        50. Victron SmartSolar manual, installation (cold Voc, Vbat + 5 V start, battery fuse): www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_100-30__100-50/e…
        51. Victron white paper, PWM or MPPT: www.victronenergy.com/upload/documents/White-paper-Which-solar-charge-…
        52. Victron Phoenix inverter datasheets (continuous, peak, efficiency, idle draw): www.victronenergy.com/upload/documents/Datasheet-Phoenix-Inverter-VE.D…
        53. 33 CFR 183.425 Table 5, conductor ampacity: www.govinfo.gov/content/pkg/CFR-2012-title33-vol2/pdf/CFR-2012-title33…
        54. Blue Sea Systems, voltage drop and wire sizing (3% rule): www.bluesea.com/support/reference/535/Voltage_Drop_in_Conductor_-_Wire…
        55. Blue Sea Systems catalog, ampacity and resistance table: catalog2015.bluesea.com/files/assets/basic-html/page-138.html
        56. NEC 690.7 and 690.8 as reproduced by Mike Holt (cold correction factors, 125% rule): www.mikeholt.com/instructor2/img/product/pdf/14SOLB-1229-sample.pdf
        57. EC&M, calculating current ratings of PV modules (the 156% rule): www.ecmweb.com/renewables/article/20896977/calculating-current-ratings…
        58. Stäubli MC4 connector datasheet (current ratings): docs.vekto.nl/media/staubli/staubli-staubli-mc4.pdf
        59. Peak sun hours, Pacific Northwest (Seattle area, 1° tilt): permitbulletin.mercerisland.gov/public/2509-066/SUB1/solar%20calculati…
        60. Peak sun hours, Northeast (Dover NH, 10° tilt): publicrecords.dover.nh.gov/FileDownload/72261/Public_Meetings/0
        61. Peak sun hours, Mid-Atlantic and Midwest (Richmond VA horizontal; Kirksville MO December): efis.psc.mo.gov/Document/Display/280931
        62. Peak sun hours, South and Texas (McAllen TX, 5° tilt): interchange.puc.texas.gov/Documents/56768_8_1443203.PDF
        63. Peak sun hours, Desert Southwest (Prescott AZ): www.yc.edu/V6/facilities/docs/Solar_Overview.pdf
        64. NREL PVWatts v8 API (month-by-month solar resource for a ZIP code): developer.nrel.gov/docs/solar/pvwatts/v8/
        65. Victron Orion XS 12/12-50 technical data (50 A alternator charger): www.victronenergy.com/media/pg/Orion_XS/en/technical-data.html
        66. Rich Solar MEGA 200 (58.7 × 26.8 in) and Renogy RSP200D G3 (58.7 × 27.5 in) and RSP200DC (1262 × 764 mm) panel sizes: richsolar.com/products/200-watt-solar-panel
        Quick answers

        RV solar questions

        How much solar do I need for my RV?

        Add up a day of use in watt-hours, multiply by 1.2 (the IEEE 1562 array-to-load ratio for non-critical loads), then divide by your region's peak sun hours, by 0.86 for PVWatts' default system losses and by 0.92 for the battery's round-trip efficiency. A fridge, lights, pump, fan on low and phones is about 650 Wh a day, which one 200 W panel covers at 5 peak sun hours. Starlink, a laptop, a TV and a microwave push that to about 1,500 Wh and 600 W of panels.

        Can I run my RV air conditioner on solar?

        Rarely. A 13,500 BTU rooftop unit draws about 1,670 W, so eight hours is roughly 14 kWh, eleven 100 Ah lithium batteries, and about 3,600 W of panels to refill. That does not fit on an RV roof. Run the AC on shore power or a generator and size solar for everything else.

        Do I need MPPT or is PWM fine?

        MPPT. Victron's own test shows a PWM controller harvesting 19% less than MPPT from the same panel at 25 °C, and the gap grows in cold weather, low light and partial shade. The price difference is small next to the panels it wastes.

        Should I wire panels in series or parallel?

        Series for most RVs: one string, one fuse, thin wire, and the controller starts earlier in the morning. The limit is the controller's PV voltage: add up the panels' open-circuit voltage and multiply by about 1.1 for a cold morning. Three 23 V panels in series is 76 V cold, fine on a 100 V controller; three of Renogy's 37 V N-type panels is 123 V, which needs a 140 or 150 V controller.

        What size fuse goes between the battery and the inverter?

        The one the inverter maker specifies, which for Renogy's P2 line is 150 A for 1,000 W, 250 A for 2,000 W and 400 A for 3,000 W. The arithmetic agrees: 2,000 W at 12.8 V and 85% efficiency is 184 A, times the 125% continuous-load rule is 230 A, so a 250 A fuse on 1/0 AWG cable rated 285 A.

        Know what to buy before you climb on the roof.

        Tap your loads, read the numbers, pick the kit.

        Size my system