Fit your RV with solar. Every part, every wire, every fuse.
Tell us what you run and where you camp. We size the battery, panels, controller, inverter, fuses and cable, then show a complete kit you can buy today. Every number traces to a manufacturer sheet, the Coast Guard wiring table or the electrical code.
- 1Panelsin series on the roof
- 2String fuseprotects the roof wire
- 3MPPTturns sun into charge
- 4LiFePO4the tank you live from
- 5Main fusewithin 7 in of the battery
- 6Inverter120 V outlets
How do you camp?
Start from the closest kit, then tap what you actually own. The kit below updates as you go.
Essentials What every RV runs
The chest-style 12 V compressor fridge most vans and small trailers carry (Dometic CFX3, ICECO), or a small residential 120 V unit. The watts shown are the maker's day-long average with the compressor cycling, so it runs 24 h.
Count the fixtures you actually switch on after dark.
Runs only while a tap is open. Twenty minutes a day covers showers and dishes for two.
A 12 V USB outlet skips the inverter. The adapter rating is the ceiling; a full charge takes about the time shown.
The upright two-door 12 V fridge built into newer trailers and motorhomes in place of a propane absorption fridge. Dometic publishes the draw while the compressor runs (156 W), not a daily average, so the hours here are compressor hours: eight a day for a cool cabin, more in summer.
The heat is propane; the 12 V side runs the fan and valves only while the burner is on. Half an hour covers two showers and the dishes.
Comfort Air, heat and sleep
Pick the speed you actually leave it on. Most nights that is low or medium.
The burner is propane; the blower is 12 V. Six hours is half of a 12 hour night, a planning figure since duty cycle depends on the weather and your insulation.
The humidifier and heated tube are most of the draw. Many campers run the device alone off grid.
Nine minutes a day is a quick dry. Short, but the inverter has to carry the whole draw.
Work and play Internet, screens, laptops
Hours of charging, not hours of use. A laptop on its own battery draws nothing from the RV.
The Mini runs straight off 12 V. The Standard dish needs the inverter unless you add a DC conversion kit.
Kitchen The 120 V heavy hitters
Ten minutes a day is a couple of reheats. The inverter must carry the full draw while it runs.
Thirty minutes at full power is a real dinner. Most cooking sits at a lower level, so this is a ceiling.
The element runs flat out only while coming to pressure, then cycles; 45 minutes of element time covers a long cook.
Big loads Possible, but plan for it
Eight hours of a 13,500 BTU unit is about 14 kWh. That is why AC is a shore-power or generator job for most 12 V rigs.
Four hours on high is 6 kWh at the battery, more than the Off-grid kit holds. Heat with propane off grid; this is for shore power.
Opens Amazon with the parts ready to add. Nothing is bought until you check out.
Wiring diagram and printable planSee every partEvery part of every kitYour exact numbers
- Battery
- Ah LiFePO4
- Solar
- W of panels
- MPPT
- A
- Inverter
- Inverter fuse
- Inverter cable
Each line is the published stand-alone PV method with your numbers; every result rounds up to the next size you can buy. Battery Ah = daily Wh × days of autonomy ÷ 12.8 V ÷ 80% usable (IEEE 1013 and the Sandia handbook). Panels W = daily Wh × 1.2 array-to-load ratio (IEEE 1562) ÷ peak sun hours ÷ 0.86 PVWatts losses ÷ 0.92 battery round trip. MPPT A = panel W ÷ 14.4 V (Victron). Inverter W = 120 V loads that run together × 1.25 (NEC continuous-load rule). Fuse = 125% of inverter current, next standard size (NEC 690.8). Where each rule comes from.
Weekender kit
positive negative panel string. Fuse and wire sizes are the kit's, from the makers' sheets and the rules below.
| Role | Part | Qty | Amazon |
|---|
Three sizes, four brands, part by part
Keep the controller, monitor and inverter from one maker and they share one app and one support line. Fuses, bus bars, switches and cable are Blue Sea and WindyNation in every kit; those are brand-neutral. Buy buttons go to Amazon; as an Amazon Associate we earn from qualifying purchases at no extra cost to you.
Weekender One 200 W panel, 100 Ah of LiFePO4, a 20 to 30 A MPPT and a 1,000 W inverter for the occasional AC gadget.
Renogy
200 W · 100 Ah · 1,000 W · 15 parts
One maker for panels, controller, battery, inverter and monitor. Specs are as published by each maker on 2026-10-13; click the source to check.
| Role | Part | Why this one | Qty | Buy |
|---|---|---|---|---|
| Solar panel | Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC) | 200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source | 1 | Buy on Amazon |
| MPPT charge controller | Renogy Rover 2 20 A MPPT (RCC-M10020-C2) | 20 A, 15 to 100 V PV input, 300 W of panels at 12 V, built-in Bluetooth source | 1 | Buy on Amazon |
| LiFePO4 battery | Renogy 12 V 100 Ah Pro, Bluetooth and self-heating (RBT12100LFP-BT) | 100 Ah, 100 A BMS, 5,000 cycles at 80% DoD, self-heating below 41 °F, 26.9 lb source | 1 | Buy on Amazon |
| Pure sine inverter (optional) | Renogy 1000 W 12 V pure sine wave (P2) | 1,000 W continuous, 2,000 W surge for 1 s, under 1 A no-load, 4 AWG 3 ft cables included source | 1 | Buy on Amazon |
| Battery monitor | Renogy 500 A battery monitor with shunt (RBM500) | 500 A shunt, 10 to 120 V, ±1% capacity accuracy, backlit display on a 20 ft lead source | 1 | Buy on Amazon |
| Battery and inverter cable (if the included cables are too short) | WindyNation 4 AWG welding and battery cable | 4 AWG pure copper, 600 V, 105 °C EPDM; 160 A at 105 °C per 33 CFR 183.425 source | 1 | Buy on Amazon |
| Inverter fuse and holder | Blue Sea Systems ANL fuse 150 A (5127) in ANL block (5005) | 150 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 1000 W source | 1 | Buy on Amazon |
| Bus bars (two) | Blue Sea Systems Common 150 A BusBar, 10 gang (2301) | 150 A DC continuous, 48 V DC, 1/4 in stud; one positive, one negative source | 2 | Buy on Amazon |
| Battery disconnect switch | Blue Sea Systems m-Series mini on-off switch (6006) | 300 A continuous, 500 A for 5 min, 48 V DC source | 1 | Buy on Amazon |
| 12 V fuse block | Blue Sea Systems ST Blade fuse block, 6 circuits (5025) | 30 A per circuit, 100 A per block, 32 V DC; feeds lights, pump, fan, USB source | 1 | Buy on Amazon |
| PV string fuse | Renogy MC4 in-line fuse holder (15 or 20 A) | 10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source | 1 | Buy on Amazon |
| PV disconnect breaker | Renogy 1P DC miniature circuit breaker, 32 A | 10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source | 1 | Buy on Amazon |
| Panel mounts | Renogy Z bracket set of 4 | Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source | 1 | Buy on Amazon |
| Roof cable entry | Renogy Double cable entry gland | UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source | 1 | Buy on Amazon |
| PV cable (roof to controller) | Renogy 10 AWG MC4 extension cable pair | 10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source | 1 | Buy on Amazon |
Rich Solar
200 W · 100 Ah · 1,000 W · 15 parts
One maker for panels, controller, battery, inverter, monitor and roof hardware. Specs are as published by each maker on 2026-10-13; click the source to check.
| Role | Part | Why this one | Qty | Buy |
|---|---|---|---|---|
| Solar panel | Rich Solar MEGA 200 (RS-M200) | 200 W, Voc 21.8 V, Vmp 18.4 V, Isc 11.6 A, 58.7 × 26.8 in, 24 lb source | 1 | Buy on Amazon |
| MPPT charge controller | Rich Solar BRAVO PRO 30 flush-mount MPPT (RS-MPPT30FB) | 30 A, 8 to 100 V PV input, 500 W of panels recommended at 12 V, Bluetooth, UL 1741 source | 1 | Buy on Amazon |
| LiFePO4 battery | Rich Solar ALPHA 1 12 V 100 Ah, Bluetooth and internal heater (RS-B121S) | 100 Ah, 1,280 Wh, 100 A continuous discharge, 5,000+ cycles at 80% DoD, 100 W heater, 24 lb The bigger kits run several in parallel: Rich Solar's ALPHA 2 200 Ah page lists only 100 A of discharge, which cannot feed a 2,000 W inverter on its own. source | 1 | Buy on Amazon |
| Pure sine inverter (optional) | Rich Solar NOVA PURE 1K 12 V (RS-V1P12) | 1,000 W continuous, 2,000 W surge, over 88% peak efficiency, under 1 A no-load, UL 458, 5.3 lb Rich Solar publishes no fuse or cable size for it, so the kit uses the 125% rule: 1,000 W at 12.8 V and 85% is 92 A, times 1.25 is 115 A, so a 150 A fuse on 4 AWG, the same pair Renogy specifies for its 1,000 W. source | 1 | Buy on Amazon |
| Battery monitor | Rich Solar 500 A battery monitor with shunt (RS-BM500) | 500 A shunt, 8 to 120 V, ±1% capacity, voltage and current accuracy source | 1 | Buy on Amazon |
| Battery and inverter cable (if the included cables are too short) | WindyNation 4 AWG welding and battery cable | 4 AWG pure copper, 600 V, 105 °C EPDM; 160 A at 105 °C per 33 CFR 183.425 source | 1 | Buy on Amazon |
| Inverter fuse and holder | Blue Sea Systems ANL fuse 150 A (5127) in ANL block (5005) | 150 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 1000 W source | 1 | Buy on Amazon |
| Bus bars (two) | Blue Sea Systems Common 150 A BusBar, 10 gang (2301) | 150 A DC continuous, 48 V DC, 1/4 in stud; one positive, one negative source | 2 | Buy on Amazon |
| Battery disconnect switch | Blue Sea Systems m-Series mini on-off switch (6006) | 300 A continuous, 500 A for 5 min, 48 V DC source | 1 | Buy on Amazon |
| 12 V fuse block | Blue Sea Systems ST Blade fuse block, 6 circuits (5025) | 30 A per circuit, 100 A per block, 32 V DC; feeds lights, pump, fan, USB source | 1 | Buy on Amazon |
| PV string fuse | Rich Solar In-line fuse holder, 20 A (RS-SC20F) | 10, 15, 20 or 30 A options, 1000 V DC, IP67. The MEGA 200 string needs 20 A (11.6 A × 1.56 = 18.1 A) source | 1 | Buy on Amazon |
| PV disconnect breaker | Renogy 1P DC miniature circuit breaker, 32 A | 10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source | 1 | Buy on Amazon |
| Panel mounts | Rich Solar Z-brackets with screws, pack of four (RS-ZB4C) | Anodized aluminum; one pack per panel, made for the MEGA panels source | 1 | Buy on Amazon |
| Roof cable entry | Rich Solar Cable entry housing (RS-C2B) | UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source | 1 | Buy on Amazon |
| PV cable (roof to controller) | Rich Solar 10 AWG solar extension cable pair, 20 ft (RS-20102) | 10 AWG, 1000 V DC, MC4-compatible ends; 20 ft pair covers most roofs source | 1 | Buy on Amazon |
Victron + Battle Born
200 W · 100 Ah · 1,000 W · 15 parts
Victron controller, monitor and inverter in one app; Battle Born batteries built in Reno. Panels are Renogy, since Victron sells none. Specs are as published by each maker on 2026-10-13; click the source to check.
| Role | Part | Why this one | Qty | Buy |
|---|---|---|---|---|
| Solar panel | Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC) | 200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source | 1 | Buy on Amazon |
| MPPT charge controller | Victron Energy SmartSolar MPPT 100/20 | 20 A, 100 V max PV, 290 W nominal PV at 12 V, Bluetooth source | 1 | Buy on Amazon |
| LiFePO4 battery | Battle Born 100 Ah 12 V LiFePO4 (BB10012) | 100 Ah, 100 A continuous, 200 A surge for 30 s, 3,000 to 5,000 cycles, cold-charging protection, 31 lb, made in Reno Battle Born's one 12 V size above 100 Ah is the 270 Ah GC3; the kits add 100 Ah units in parallel instead. source | 1 | Buy on Amazon |
| Pure sine inverter (optional) | Victron Energy Phoenix Inverter 12/1200 VE.Direct, 120 V | 1,200 VA: 1,000 W continuous at 25 °C, 850 W at 40 °C, 2,200 W peak, 91% max efficiency, 10 W no-load; internal 200 A fuse Victron's manual requires a fuse near the battery for cable runs over 1.5 m and for the UL units, and calls for 25 mm² cable, between 4 and 2 AWG; the kit lists 1/0 AWG, the next size we carry, with a 150 A fuse by the 125% rule. source | 1 | Buy on Amazon |
| Battery monitor | Victron Energy SmartShunt 500 A | 500 A shunt, 6.5 to 70 V, Bluetooth app shows state of charge source | 1 | Buy on Amazon |
| Battery and inverter cable | WindyNation 1/0 AWG welding and battery cable, 10 ft red and 10 ft black | 1/0 AWG pure copper, 600 V, 105 °C EPDM; 285 A at 105 °C per 33 CFR 183.425 source | 1 | Buy on Amazon |
| Inverter fuse and holder | Blue Sea Systems ANL fuse 150 A (5127) in ANL block (5005) | 150 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 1000 W source | 1 | Buy on Amazon |
| Bus bars (two) | Blue Sea Systems Common 150 A BusBar, 10 gang (2301) | 150 A DC continuous, 48 V DC, 1/4 in stud; one positive, one negative source | 2 | Buy on Amazon |
| Battery disconnect switch | Blue Sea Systems m-Series mini on-off switch (6006) | 300 A continuous, 500 A for 5 min, 48 V DC source | 1 | Buy on Amazon |
| 12 V fuse block | Blue Sea Systems ST Blade fuse block, 6 circuits (5025) | 30 A per circuit, 100 A per block, 32 V DC; feeds lights, pump, fan, USB source | 1 | Buy on Amazon |
| PV string fuse | Renogy MC4 in-line fuse holder (15 or 20 A) | 10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source | 1 | Buy on Amazon |
| PV disconnect breaker | Renogy 1P DC miniature circuit breaker, 32 A | 10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source | 1 | Buy on Amazon |
| Panel mounts | Renogy Z bracket set of 4 | Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source | 1 | Buy on Amazon |
| Roof cable entry | Renogy Double cable entry gland | UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source | 1 | Buy on Amazon |
| PV cable (roof to controller) | Renogy 10 AWG MC4 extension cable pair | 10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source | 1 | Buy on Amazon |
Value mix
200 W · 100 Ah · 1,000 W · 15 parts
Victron controller and monitor, LiTime battery, Renogy panels and inverter: the lowest price for the same numbers. Specs are as published by each maker on 2026-10-13; click the source to check.
| Role | Part | Why this one | Qty | Buy |
|---|---|---|---|---|
| Solar panel | Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC) | 200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source | 1 | Buy on Amazon |
| MPPT charge controller | Victron Energy SmartSolar MPPT 100/20 | 20 A, 100 V max PV, 290 W nominal PV at 12 V, Bluetooth source | 1 | Buy on Amazon |
| LiFePO4 battery | LiTime 12 V 100 Ah LiFePO4 (Group 31) | 100 Ah, 1,280 Wh, 100 A BMS, 4,000 cycles at 100% DoD, 24 lb source | 1 | Buy on Amazon |
| Pure sine inverter (optional) | Renogy 1000 W 12 V pure sine wave (P2) | 1,000 W continuous, 2,000 W surge for 1 s, under 1 A no-load, 4 AWG 3 ft cables included source | 1 | Buy on Amazon |
| Battery monitor | Victron Energy SmartShunt 500 A | 500 A shunt, 6.5 to 70 V, Bluetooth app shows state of charge source | 1 | Buy on Amazon |
| Battery and inverter cable (if the included cables are too short) | WindyNation 4 AWG welding and battery cable | 4 AWG pure copper, 600 V, 105 °C EPDM; 160 A at 105 °C per 33 CFR 183.425 source | 1 | Buy on Amazon |
| Inverter fuse and holder | Blue Sea Systems ANL fuse 150 A (5127) in ANL block (5005) | 150 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 1000 W source | 1 | Buy on Amazon |
| Bus bars (two) | Blue Sea Systems Common 150 A BusBar, 10 gang (2301) | 150 A DC continuous, 48 V DC, 1/4 in stud; one positive, one negative source | 2 | Buy on Amazon |
| Battery disconnect switch | Blue Sea Systems m-Series mini on-off switch (6006) | 300 A continuous, 500 A for 5 min, 48 V DC source | 1 | Buy on Amazon |
| 12 V fuse block | Blue Sea Systems ST Blade fuse block, 6 circuits (5025) | 30 A per circuit, 100 A per block, 32 V DC; feeds lights, pump, fan, USB source | 1 | Buy on Amazon |
| PV string fuse | Renogy MC4 in-line fuse holder (15 or 20 A) | 10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source | 1 | Buy on Amazon |
| PV disconnect breaker | Renogy 1P DC miniature circuit breaker, 32 A | 10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source | 1 | Buy on Amazon |
| Panel mounts | Renogy Z bracket set of 4 | Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source | 1 | Buy on Amazon |
| Roof cable entry | Renogy Double cable entry gland | UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source | 1 | Buy on Amazon |
| PV cable (roof to controller) | Renogy 10 AWG MC4 extension cable pair | 10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source | 1 | Buy on Amazon |
Full-timer Three 200 W panels in series, 200 Ah of LiFePO4, a 60 A MPPT and a 2,000 W class inverter that runs an RV microwave.
Renogy
600 W · 200 Ah · 2,000 W · 15 parts
One maker for panels, controller, battery, inverter and monitor. Specs are as published by each maker on 2026-10-13; click the source to check.
| Role | Part | Why this one | Qty | Buy |
|---|---|---|---|---|
| Solar panel | Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC) | 200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source | 3 | Buy on Amazon |
| MPPT charge controller | Renogy Rover 60 A MPPT (RNG-CTRL-RVR60) | 60 A, 140 V max PV input, 800 W of panels at 12 V; Bluetooth with the BT-2 module source | 1 | Buy on Amazon |
| LiFePO4 battery | Renogy 12 V 100 Ah Pro, Bluetooth and self-heating (RBT12100LFP-BT) | 100 Ah, 100 A BMS, 5,000 cycles at 80% DoD, self-heating below 41 °F, 26.9 lb source | 2 | Buy on Amazon |
| Pure sine inverter | Renogy 2000 W 12 V pure sine wave (P2) | 2,000 W continuous, 4,000 W surge for 1 s, under 2 A no-load, 1/0 AWG 3 ft cables included source | 1 | Buy on Amazon |
| Battery monitor | Renogy 500 A battery monitor with shunt (RBM500) | 500 A shunt, 10 to 120 V, ±1% capacity accuracy, backlit display on a 20 ft lead source | 1 | Buy on Amazon |
| Battery and inverter cable (if the included cables are too short) | WindyNation 1/0 AWG welding and battery cable, 10 ft red and 10 ft black | 1/0 AWG pure copper, 600 V, 105 °C EPDM; 285 A at 105 °C per 33 CFR 183.425 source | 1 | Buy on Amazon |
| Inverter fuse and holder | Blue Sea Systems ANL fuse 250 A (5131) in ANL block (5005) | 250 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 2000 W source | 1 | Buy on Amazon |
| Bus bars (two) | Blue Sea Systems MaxiBus 250 A (2127) | 250 A continuous, 48 V DC, four 5/16 in studs; one positive, one negative source | 2 | Buy on Amazon |
| Battery disconnect switch | Blue Sea Systems m-Series mini on-off switch (6006) | 300 A continuous, 500 A for 5 min, 48 V DC source | 1 | Buy on Amazon |
| 12 V fuse block | Blue Sea Systems ST Blade fuse block, 12 circuits (5026) | 30 A per circuit, 100 A per block, 32 V DC, negative bus source | 1 | Buy on Amazon |
| PV string fuse | Renogy MC4 in-line fuse holder (15 or 20 A) | 10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source | 1 | Buy on Amazon |
| PV disconnect breaker | Renogy 1P DC miniature circuit breaker, 32 A | 10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source | 1 | Buy on Amazon |
| Panel mounts | Renogy Z bracket set of 4 | Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source | 3 | Buy on Amazon |
| Roof cable entry | Renogy Double cable entry gland | UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source | 1 | Buy on Amazon |
| PV cable (roof to controller) | Renogy 10 AWG MC4 extension cable pair | 10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source | 1 | Buy on Amazon |
Rich Solar
600 W · 200 Ah · 2,000 W · 15 parts
One maker for panels, controller, battery, inverter, monitor and roof hardware. Specs are as published by each maker on 2026-10-13; click the source to check.
| Role | Part | Why this one | Qty | Buy |
|---|---|---|---|---|
| Solar panel | Rich Solar MEGA 200 (RS-M200) | 200 W, Voc 21.8 V, Vmp 18.4 V, Isc 11.6 A, 58.7 × 26.8 in, 24 lb source | 3 | Buy on Amazon |
| MPPT charge controller | Rich Solar BRAVO 60 MPPT (RS-MPPT60P) | 60 A, 100 V max PV open-circuit voltage, 900 W of panels recommended at 12 V, Bluetooth The Off-grid kit wires its four MEGA 200 as two strings of two (about 50 V cold). Four in one string would be about 99 V on a −10 °C morning, too close to the 100 V limit. source | 1 | Buy on Amazon |
| LiFePO4 battery | Rich Solar ALPHA 1 12 V 100 Ah, Bluetooth and internal heater (RS-B121S) | 100 Ah, 1,280 Wh, 100 A continuous discharge, 5,000+ cycles at 80% DoD, 100 W heater, 24 lb The bigger kits run several in parallel: Rich Solar's ALPHA 2 200 Ah page lists only 100 A of discharge, which cannot feed a 2,000 W inverter on its own. source | 2 | Buy on Amazon |
| Pure sine inverter | Rich Solar NOVA PURE 2K 12 V (RS-V2P12) | 2,000 W continuous, 4,000 W surge, over 88% peak efficiency, under 2 A no-load, UL 458, 10.1 lb No fuse or cable size is published, so the kit uses the 125% rule: 184 A times 1.25 is 230 A, so a 250 A fuse on 1/0 AWG, the pair Renogy specifies for its 2,000 W. source | 1 | Buy on Amazon |
| Battery monitor | Rich Solar 500 A battery monitor with shunt (RS-BM500) | 500 A shunt, 8 to 120 V, ±1% capacity, voltage and current accuracy source | 1 | Buy on Amazon |
| Battery and inverter cable (if the included cables are too short) | WindyNation 1/0 AWG welding and battery cable, 10 ft red and 10 ft black | 1/0 AWG pure copper, 600 V, 105 °C EPDM; 285 A at 105 °C per 33 CFR 183.425 source | 1 | Buy on Amazon |
| Inverter fuse and holder | Blue Sea Systems ANL fuse 250 A (5131) in ANL block (5005) | 250 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 2000 W source | 1 | Buy on Amazon |
| Bus bars (two) | Blue Sea Systems MaxiBus 250 A (2127) | 250 A continuous, 48 V DC, four 5/16 in studs; one positive, one negative source | 2 | Buy on Amazon |
| Battery disconnect switch | Blue Sea Systems m-Series mini on-off switch (6006) | 300 A continuous, 500 A for 5 min, 48 V DC source | 1 | Buy on Amazon |
| 12 V fuse block | Blue Sea Systems ST Blade fuse block, 12 circuits (5026) | 30 A per circuit, 100 A per block, 32 V DC, negative bus source | 1 | Buy on Amazon |
| PV string fuse | Rich Solar In-line fuse holder, 20 A (RS-SC20F) | 10, 15, 20 or 30 A options, 1000 V DC, IP67. The MEGA 200 string needs 20 A (11.6 A × 1.56 = 18.1 A) source | 1 | Buy on Amazon |
| PV disconnect breaker | Renogy 1P DC miniature circuit breaker, 32 A | 10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source | 1 | Buy on Amazon |
| Panel mounts | Rich Solar Z-brackets with screws, pack of four (RS-ZB4C) | Anodized aluminum; one pack per panel, made for the MEGA panels source | 3 | Buy on Amazon |
| Roof cable entry | Rich Solar Cable entry housing (RS-C2B) | UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source | 1 | Buy on Amazon |
| PV cable (roof to controller) | Rich Solar 10 AWG solar extension cable pair, 20 ft (RS-20102) | 10 AWG, 1000 V DC, MC4-compatible ends; 20 ft pair covers most roofs source | 1 | Buy on Amazon |
Victron + Battle Born
600 W · 200 Ah · 1,600 W · 15 parts
Victron controller, monitor and inverter in one app; Battle Born batteries built in Reno. Panels are Renogy, since Victron sells none. Specs are as published by each maker on 2026-10-13; click the source to check.
| Role | Part | Why this one | Qty | Buy |
|---|---|---|---|---|
| Solar panel | Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC) | 200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source | 3 | Buy on Amazon |
| MPPT charge controller | Victron Energy SmartSolar MPPT 150/60 | 60 A, 150 V max PV, 860 W nominal PV at 12 V, Bluetooth source | 1 | Buy on Amazon |
| LiFePO4 battery | Battle Born 100 Ah 12 V LiFePO4 (BB10012) | 100 Ah, 100 A continuous, 200 A surge for 30 s, 3,000 to 5,000 cycles, cold-charging protection, 31 lb, made in Reno Battle Born's one 12 V size above 100 Ah is the 270 Ah GC3; the kits add 100 Ah units in parallel instead. source | 2 | Buy on Amazon |
| Pure sine inverter | Victron Energy Phoenix Inverter Smart 12/2000, 120 V | 2,000 VA: 1,600 W continuous at 25 °C, 4,000 W peak, 92% max efficiency, 8 W no-load, Bluetooth; Victron specifies a 300 A fuse and 70 mm² cable Victron's datasheet lists 350 to 1,000 Ah of battery behind this inverter; two Battle Borns run it, four is Victron's comfort zone. 70 mm² sits between 2/0 and 4/0 AWG, so the kit lists 4/0. source | 1 | Buy on Amazon |
| Battery monitor | Victron Energy SmartShunt 500 A | 500 A shunt, 6.5 to 70 V, Bluetooth app shows state of charge source | 1 | Buy on Amazon |
| Battery and inverter cable | WindyNation 4/0 AWG welding and battery cable | 4/0 AWG pure copper, 600 V, 105 °C EPDM; 445 A at 105 °C per 33 CFR 183.425 source | 1 | Buy on Amazon |
| Inverter fuse and holder | Blue Sea Systems Class T fuse 300 A (5119) in Class T block (5502) | 300 A, 125 V DC, 20,000 A interrupt; the fuse Victron specifies for the 12/2000 The cart adds the block; the 300 A fuse itself opens an Amazon search. source | 1 | Buy on Amazon |
| Bus bars (two) | Blue Sea Systems MaxiBus 250 A (2127) | 250 A continuous, 48 V DC, four 5/16 in studs; one positive, one negative source | 2 | Buy on Amazon |
| Battery disconnect switch | Blue Sea Systems m-Series mini on-off switch (6006) | 300 A continuous, 500 A for 5 min, 48 V DC source | 1 | Buy on Amazon |
| 12 V fuse block | Blue Sea Systems ST Blade fuse block, 12 circuits (5026) | 30 A per circuit, 100 A per block, 32 V DC, negative bus source | 1 | Buy on Amazon |
| PV string fuse | Renogy MC4 in-line fuse holder (15 or 20 A) | 10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source | 1 | Buy on Amazon |
| PV disconnect breaker | Renogy 1P DC miniature circuit breaker, 32 A | 10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source | 1 | Buy on Amazon |
| Panel mounts | Renogy Z bracket set of 4 | Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source | 3 | Buy on Amazon |
| Roof cable entry | Renogy Double cable entry gland | UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source | 1 | Buy on Amazon |
| PV cable (roof to controller) | Renogy 10 AWG MC4 extension cable pair | 10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source | 1 | Buy on Amazon |
Value mix
600 W · 200 Ah · 2,000 W · 15 parts
Victron controller and monitor, LiTime battery, Renogy panels and inverter: the lowest price for the same numbers. Specs are as published by each maker on 2026-10-13; click the source to check.
| Role | Part | Why this one | Qty | Buy |
|---|---|---|---|---|
| Solar panel | Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC) | 200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source | 3 | Buy on Amazon |
| MPPT charge controller | Victron Energy SmartSolar MPPT 150/60 | 60 A, 150 V max PV, 860 W nominal PV at 12 V, Bluetooth source | 1 | Buy on Amazon |
| LiFePO4 battery | LiTime 12 V 200 Ah Plus LiFePO4 | 200 Ah, 2,560 Wh, 200 A BMS, 4,000 cycles at 100% DoD, 48 lb source | 1 | Buy on Amazon |
| Pure sine inverter | Renogy 2000 W 12 V pure sine wave (P2) | 2,000 W continuous, 4,000 W surge for 1 s, under 2 A no-load, 1/0 AWG 3 ft cables included source | 1 | Buy on Amazon |
| Battery monitor | Victron Energy SmartShunt 500 A | 500 A shunt, 6.5 to 70 V, Bluetooth app shows state of charge source | 1 | Buy on Amazon |
| Battery and inverter cable (if the included cables are too short) | WindyNation 1/0 AWG welding and battery cable, 10 ft red and 10 ft black | 1/0 AWG pure copper, 600 V, 105 °C EPDM; 285 A at 105 °C per 33 CFR 183.425 source | 1 | Buy on Amazon |
| Inverter fuse and holder | Blue Sea Systems ANL fuse 250 A (5131) in ANL block (5005) | 250 A, 80 V DC, 6,000 A interrupt; the fuse Renogy specifies for the 2000 W source | 1 | Buy on Amazon |
| Bus bars (two) | Blue Sea Systems MaxiBus 250 A (2127) | 250 A continuous, 48 V DC, four 5/16 in studs; one positive, one negative source | 2 | Buy on Amazon |
| Battery disconnect switch | Blue Sea Systems m-Series mini on-off switch (6006) | 300 A continuous, 500 A for 5 min, 48 V DC source | 1 | Buy on Amazon |
| 12 V fuse block | Blue Sea Systems ST Blade fuse block, 12 circuits (5026) | 30 A per circuit, 100 A per block, 32 V DC, negative bus source | 1 | Buy on Amazon |
| PV string fuse | Renogy MC4 in-line fuse holder (15 or 20 A) | 10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source | 1 | Buy on Amazon |
| PV disconnect breaker | Renogy 1P DC miniature circuit breaker, 32 A | 10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source | 1 | Buy on Amazon |
| Panel mounts | Renogy Z bracket set of 4 | Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source | 3 | Buy on Amazon |
| Roof cable entry | Renogy Double cable entry gland | UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source | 1 | Buy on Amazon |
| PV cable (roof to controller) | Renogy 10 AWG MC4 extension cable pair | 10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source | 1 | Buy on Amazon |
Off-grid Four 200 W panels, 400 Ah of LiFePO4, a 60 A MPPT, a 3,000 W class inverter and an alternator charger for cloudy weeks.
Renogy
800 W · 400 Ah · 3,000 W · 17 parts
One maker for panels, controller, battery, inverter and monitor. Specs are as published by each maker on 2026-10-13; click the source to check.
| Role | Part | Why this one | Qty | Buy |
|---|---|---|---|---|
| Solar panel | Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC) | 200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source | 4 | Buy on Amazon |
| MPPT charge controller | Renogy Rover 60 A MPPT (RNG-CTRL-RVR60) | 60 A, 140 V max PV input, 800 W of panels at 12 V; Bluetooth with the BT-2 module source | 1 | Buy on Amazon |
| LiFePO4 battery | Renogy 12 V 100 Ah Pro, Bluetooth and self-heating (RBT12100LFP-BT) | 100 Ah, 100 A BMS, 5,000 cycles at 80% DoD, self-heating below 41 °F, 26.9 lb source | 4 | Buy on Amazon |
| Pure sine inverter | Renogy 3000 W 12 V pure sine wave (P2) | 3,000 W continuous, 6,000 W surge for 1 s, under 2.5 A no-load, 4/0 AWG recommended source | 1 | Buy on Amazon |
| Battery monitor | Renogy 500 A battery monitor with shunt (RBM500) | 500 A shunt, 10 to 120 V, ±1% capacity accuracy, backlit display on a 20 ft lead source | 1 | Buy on Amazon |
| Battery and inverter cable | WindyNation 4/0 AWG welding and battery cable | 4/0 AWG pure copper, 600 V, 105 °C EPDM; 445 A at 105 °C per 33 CFR 183.425 source | 1 | Buy on Amazon |
| Inverter fuse and holder | Blue Sea Systems Class T fuse 400 A (5121) in Class T block (5502) | 400 A, 125 V DC, 20,000 A interrupt; the fuse Renogy specifies for the 3000 W source | 1 | Buy on Amazon |
| Bus bars (two) | Blue Sea Systems PowerBar 1000 A (1991) | 1,000 A continuous, 150 V, twelve 3/8 in studs; one positive, one negative source | 2 | Buy on Amazon |
| Battery disconnect switch | Blue Sea Systems e-Series on-off switch (9003e) | 350 A continuous, 600 A for 5 min, 48 V DC source | 1 | Buy on Amazon |
| 12 V fuse block | Blue Sea Systems ST Blade fuse block, 12 circuits (5026) | 30 A per circuit, 100 A per block, 32 V DC, negative bus source | 1 | Buy on Amazon |
| PV string fuse | Renogy MC4 in-line fuse holder (15 or 20 A) | 10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source | 2 | Buy on Amazon |
| PV disconnect breaker | Renogy 1P DC miniature circuit breaker, 32 A | 10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source | 1 | Buy on Amazon |
| Panel mounts | Renogy Z bracket set of 4 | Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source | 4 | Buy on Amazon |
| Roof cable entry | Renogy Double cable entry gland | UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source | 1 | Buy on Amazon |
| PV cable (roof to controller) | Renogy 10 AWG MC4 extension cable pair | 10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source | 1 | Buy on Amazon |
| MC4 branch connectors | Renogy Y branch pair, 2 to 1 | 30 A, 1500 V DC, IP67; only if you wire panels in parallel source | 1 | Buy on Amazon |
| DC-DC alternator charger (optional) (optional) | Renogy 12 V 50 A DC-DC on-board charger with MPPT (DCC50S) | 50 A from the alternator while driving; also takes up to 660 W of solar at 50 V source | 1 | Buy on Amazon |
Rich Solar
800 W · 400 Ah · 3,000 W · 17 parts
One maker for panels, controller, battery, inverter, monitor and roof hardware. Specs are as published by each maker on 2026-10-13; click the source to check.
| Role | Part | Why this one | Qty | Buy |
|---|---|---|---|---|
| Solar panel | Rich Solar MEGA 200 (RS-M200) | 200 W, Voc 21.8 V, Vmp 18.4 V, Isc 11.6 A, 58.7 × 26.8 in, 24 lb source | 4 | Buy on Amazon |
| MPPT charge controller | Rich Solar BRAVO 60 MPPT (RS-MPPT60P) | 60 A, 100 V max PV open-circuit voltage, 900 W of panels recommended at 12 V, Bluetooth The Off-grid kit wires its four MEGA 200 as two strings of two (about 50 V cold). Four in one string would be about 99 V on a −10 °C morning, too close to the 100 V limit. source | 1 | Buy on Amazon |
| LiFePO4 battery | Rich Solar ALPHA 1 12 V 100 Ah, Bluetooth and internal heater (RS-B121S) | 100 Ah, 1,280 Wh, 100 A continuous discharge, 5,000+ cycles at 80% DoD, 100 W heater, 24 lb The bigger kits run several in parallel: Rich Solar's ALPHA 2 200 Ah page lists only 100 A of discharge, which cannot feed a 2,000 W inverter on its own. source | 4 | Buy on Amazon |
| Pure sine inverter | Rich Solar NOVA PURE 3K 12 V (RS-V3P12) | 3,000 W continuous, 6,000 W surge, over 88% peak efficiency, under 2 A no-load, UL 458, 12.1 lb No fuse or cable size is published, so the kit uses the 125% rule: 276 A times 1.25 is 345 A, so a 400 A Class T on 4/0 AWG, the pair Renogy specifies for its 3,000 W. source | 1 | Buy on Amazon |
| Battery monitor | Rich Solar 500 A battery monitor with shunt (RS-BM500) | 500 A shunt, 8 to 120 V, ±1% capacity, voltage and current accuracy source | 1 | Buy on Amazon |
| Battery and inverter cable | WindyNation 4/0 AWG welding and battery cable | 4/0 AWG pure copper, 600 V, 105 °C EPDM; 445 A at 105 °C per 33 CFR 183.425 source | 1 | Buy on Amazon |
| Inverter fuse and holder | Blue Sea Systems Class T fuse 400 A (5121) in Class T block (5502) | 400 A, 125 V DC, 20,000 A interrupt; the fuse Renogy specifies for the 3000 W source | 1 | Buy on Amazon |
| Bus bars (two) | Blue Sea Systems PowerBar 1000 A (1991) | 1,000 A continuous, 150 V, twelve 3/8 in studs; one positive, one negative source | 2 | Buy on Amazon |
| Battery disconnect switch | Blue Sea Systems e-Series on-off switch (9003e) | 350 A continuous, 600 A for 5 min, 48 V DC source | 1 | Buy on Amazon |
| 12 V fuse block | Blue Sea Systems ST Blade fuse block, 12 circuits (5026) | 30 A per circuit, 100 A per block, 32 V DC, negative bus source | 1 | Buy on Amazon |
| PV string fuse | Rich Solar In-line fuse holder, 20 A (RS-SC20F) | 10, 15, 20 or 30 A options, 1000 V DC, IP67. The MEGA 200 string needs 20 A (11.6 A × 1.56 = 18.1 A) source | 2 | Buy on Amazon |
| PV disconnect breaker | Renogy 1P DC miniature circuit breaker, 32 A | 10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source | 1 | Buy on Amazon |
| Panel mounts | Rich Solar Z-brackets with screws, pack of four (RS-ZB4C) | Anodized aluminum; one pack per panel, made for the MEGA panels source | 4 | Buy on Amazon |
| Roof cable entry | Rich Solar Cable entry housing (RS-C2B) | UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source | 1 | Buy on Amazon |
| PV cable (roof to controller) | Rich Solar 10 AWG solar extension cable pair, 20 ft (RS-20102) | 10 AWG, 1000 V DC, MC4-compatible ends; 20 ft pair covers most roofs source | 1 | Buy on Amazon |
| MC4 branch connectors | Renogy Y branch pair, 2 to 1 | 30 A, 1500 V DC, IP67; only if you wire panels in parallel source | 1 | Buy on Amazon |
| DC-DC alternator charger (optional) (optional) | Rich Solar 12 V 40 A DC-DC battery charger (RS-DC40) | 40 A from the alternator while driving, 10 to 16 V input; manual calls for a 60 A input fuse, 50 A output fuse, 6 AWG in and 8 AWG out source | 1 | Buy on Amazon |
Victron + Battle Born
800 W · 400 Ah · 2,400 W · 17 parts
Victron controller, monitor and inverter in one app; Battle Born batteries built in Reno. Panels are Renogy, since Victron sells none. Specs are as published by each maker on 2026-10-13; click the source to check.
| Role | Part | Why this one | Qty | Buy |
|---|---|---|---|---|
| Solar panel | Renogy 200 W monocrystalline (RSP200D G3 or the newer N-type RSP200DC) | 200 W either way. G3: Voc 23 V, Isc 11.05 A, 20 A series fuse, 26.4 lb. N-type: Voc 37.44 V, Isc 6.85 A, 15 A series fuse, 23.4 lb The listing is the N-type RSP200DC; a G3 can still arrive from another seller under the same name. The kit is sized so either works; read the label on the back before wiring in series and pick the string fuse to match. source | 4 | Buy on Amazon |
| MPPT charge controller | Victron Energy SmartSolar MPPT 150/60 | 60 A, 150 V max PV, 860 W nominal PV at 12 V, Bluetooth source | 1 | Buy on Amazon |
| LiFePO4 battery | Battle Born 100 Ah 12 V LiFePO4 (BB10012) | 100 Ah, 100 A continuous, 200 A surge for 30 s, 3,000 to 5,000 cycles, cold-charging protection, 31 lb, made in Reno Battle Born's one 12 V size above 100 Ah is the 270 Ah GC3; the kits add 100 Ah units in parallel instead. source | 4 | Buy on Amazon |
| Pure sine inverter | Victron Energy Phoenix Inverter Smart 12/3000, 120 V | 3,000 VA: 2,400 W continuous at 25 °C, 6,000 W peak, 93% max efficiency, 12 W no-load, Bluetooth; Victron specifies a 400 A fuse and 90 mm² cable Victron lists 400 to 1,200 Ah of battery for it; the kit's four Battle Borns are the floor. source | 1 | Buy on Amazon |
| Battery monitor | Victron Energy SmartShunt 500 A | 500 A shunt, 6.5 to 70 V, Bluetooth app shows state of charge source | 1 | Buy on Amazon |
| Battery and inverter cable | WindyNation 4/0 AWG welding and battery cable | 4/0 AWG pure copper, 600 V, 105 °C EPDM; 445 A at 105 °C per 33 CFR 183.425 source | 1 | Buy on Amazon |
| Inverter fuse and holder | Blue Sea Systems Class T fuse 400 A (5121) in Class T block (5502) | 400 A, 125 V DC, 20,000 A interrupt; the fuse Renogy specifies for the 3000 W source | 1 | Buy on Amazon |
| Bus bars (two) | Blue Sea Systems PowerBar 1000 A (1991) | 1,000 A continuous, 150 V, twelve 3/8 in studs; one positive, one negative source | 2 | Buy on Amazon |
| Battery disconnect switch | Blue Sea Systems e-Series on-off switch (9003e) | 350 A continuous, 600 A for 5 min, 48 V DC source | 1 | Buy on Amazon |
| 12 V fuse block | Blue Sea Systems ST Blade fuse block, 12 circuits (5026) | 30 A per circuit, 100 A per block, 32 V DC, negative bus source | 1 | Buy on Amazon |
| PV string fuse | Renogy MC4 in-line fuse holder (15 or 20 A) | 10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source | 2 | Buy on Amazon |
| PV disconnect breaker | Renogy 1P DC miniature circuit breaker, 32 A | 10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source | 1 | Buy on Amazon |
| Panel mounts | Renogy Z bracket set of 4 | Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source | 4 | Buy on Amazon |
| Roof cable entry | Renogy Double cable entry gland | UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source | 1 | Buy on Amazon |
| PV cable (roof to controller) | Renogy 10 AWG MC4 extension cable pair | 10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source | 1 | Buy on Amazon |
| MC4 branch connectors | Renogy Y branch pair, 2 to 1 | 30 A, 1500 V DC, IP67; only if you wire panels in parallel source | 1 | Buy on Amazon |
| DC-DC alternator charger (optional) (optional) | Victron Energy Orion XS 12/12-50 A | 50 A from the alternator while driving, 98.5% efficient; the rainy-week backstop source | 1 | Buy on Amazon |
Value mix
800 W · 400 Ah · 3,000 W · 16 parts
Victron controller and monitor, LiTime battery, Renogy panels and inverter: the lowest price for the same numbers. Specs are as published by each maker on 2026-10-13; click the source to check.
| Role | Part | Why this one | Qty | Buy |
|---|---|---|---|---|
| Solar panel | Rich Solar MEGA 200 (RS-M200) | 200 W, Voc 21.8 V, Vmp 18.4 V, Isc 11.6 A, 58.7 × 26.8 in, 24 lb source | 4 | Buy on Amazon |
| MPPT charge controller | Victron Energy SmartSolar MPPT 150/60 | 60 A, 150 V max PV, 860 W nominal PV at 12 V, Bluetooth source | 1 | Buy on Amazon |
| LiFePO4 battery | LiTime 12 V 200 Ah Plus LiFePO4 | 200 Ah, 2,560 Wh, 200 A BMS, 4,000 cycles at 100% DoD, 48 lb source | 2 | Buy on Amazon |
| Pure sine inverter | Renogy 3000 W 12 V pure sine wave (P2) | 3,000 W continuous, 6,000 W surge for 1 s, under 2.5 A no-load, 4/0 AWG recommended source | 1 | Buy on Amazon |
| Battery monitor | Victron Energy SmartShunt 500 A | 500 A shunt, 6.5 to 70 V, Bluetooth app shows state of charge source | 1 | Buy on Amazon |
| Battery and inverter cable | WindyNation 4/0 AWG welding and battery cable | 4/0 AWG pure copper, 600 V, 105 °C EPDM; 445 A at 105 °C per 33 CFR 183.425 source | 1 | Buy on Amazon |
| Inverter fuse and holder | Blue Sea Systems Class T fuse 400 A (5121) in Class T block (5502) | 400 A, 125 V DC, 20,000 A interrupt; the fuse Renogy specifies for the 3000 W source | 1 | Buy on Amazon |
| Bus bars (two) | Blue Sea Systems PowerBar 1000 A (1991) | 1,000 A continuous, 150 V, twelve 3/8 in studs; one positive, one negative source | 2 | Buy on Amazon |
| Battery disconnect switch | Blue Sea Systems e-Series on-off switch (9003e) | 350 A continuous, 600 A for 5 min, 48 V DC source | 1 | Buy on Amazon |
| 12 V fuse block | Blue Sea Systems ST Blade fuse block, 12 circuits (5026) | 30 A per circuit, 100 A per block, 32 V DC, negative bus source | 1 | Buy on Amazon |
| PV string fuse | Renogy MC4 in-line fuse holder (15 or 20 A) | 10, 15, 20 or 30 A options, waterproof MC4 ends. Size it at 156% of the panel's Isc and never above the panel's series-fuse rating: 20 A for the G3 or Rich Solar, 15 A for the N-type source | 1 | Buy on Amazon |
| PV disconnect breaker | Renogy 1P DC miniature circuit breaker, 32 A | 10, 16, 32, 50 or 63 A options, 250 V, 6 kA breaking; a switch to isolate the roof before touching the controller. The MC4 fuse is what protects the string, so the breaker is sized above it source | 1 | Buy on Amazon |
| Panel mounts | Renogy Z bracket set of 4 | Aluminum, M6 hardware and self-drilling screws; one set per panel, rated for panels up to 200 W source | 4 | Buy on Amazon |
| Roof cable entry | Renogy Double cable entry gland | UV-resistant ABS, fits 6 to 12 mm cable; seal with lap sealant source | 1 | Buy on Amazon |
| PV cable (roof to controller) | Renogy 10 AWG MC4 extension cable pair | 10 AWG, 600/1000 V, −40 to 185 °F; 20 ft pair covers most roofs source | 1 | Buy on Amazon |
| DC-DC alternator charger (optional) (optional) | Victron Energy Orion XS 12/12-50 A | 50 A from the alternator while driving, 98.5% efficient; the rainy-week backstop source | 1 | Buy on Amazon |
How it goes together, and why each number is what it is
Install order, string voltage and fuses
Install order
- Mount the panels with Z brackets and lap sealant. Wire each string in series: positive of one panel to negative of the next, so the volts add. Most kits are one string with one pair of 10 AWG leads; the Off-grid kits on Renogy panels and the Rich Solar Off-grid kit are two strings of two, each with its own fuse, joined in parallel (positive to positive, negative to negative) with branch connectors after the fuses.
- Fuse the string with an MC4 in-line fuse at 156% of the panel's short-circuit current (NEC 690.8), then bring the leads through the roof gland to a DC breaker you can switch off before touching anything.
- Connect battery before panels. The controller needs to see the battery first; Victron's manual requires the PV voltage to be at least 5 V above the battery to start and below the controller's limit on the coldest morning.
- Bus bars take the load. Battery to a disconnect switch, then the main fuse within 7 inches of the battery terminal, then the positive bus bar. Controller, inverter and the 12 V fuse block all land on the bus bars, never stacked on one battery post.
- Inverter on its own fuse and cable as its manual specifies: 150 A and 4 AWG for 1,000 W, 250 A and 1/0 AWG for 2,000 W, 400 A and 4/0 AWG for 3,000 W. Keep the run under 3 ft.
- Shunt on the negative. Every negative goes to the battery through the SmartShunt so the app shows a true state of charge.
String voltage on a cold morning
| Kit and panel | In series | Voc at 25 °C | Voc at −10 °C | Controller limit |
|---|---|---|---|---|
| Weekender (Renogy), RSP200D G3 | 1 | 23.0 V | 25.3 V | 100 V |
| Weekender (Renogy), RSP200DC N-type | 1 | 37.4 V | 41.1 V | 100 V |
| Full-timer (Renogy), RSP200D G3 | 3 | 69.0 V | 75.8 V | 140 V |
| Full-timer (Renogy), RSP200DC N-type | 3 | 112.3 V | 123.3 V | 140 V |
| Off-grid (Renogy), RSP200D G3 | 2 × 2 strings | 46.0 V | 50.5 V | 140 V |
| Off-grid (Renogy), RSP200DC N-type | 2 × 2 strings | 74.9 V | 82.2 V | 140 V |
| Weekender (Rich Solar), MEGA 200 | 1 | 21.8 V | 24.9 V | 100 V |
| Full-timer (Rich Solar), MEGA 200 | 3 | 65.4 V | 74.6 V | 100 V |
| Off-grid (Rich Solar), MEGA 200 | 2 × 2 strings | 43.6 V | 49.7 V | 100 V |
| Weekender (Victron + Battle Born), RSP200D G3 | 1 | 23.0 V | 25.3 V | 100 V |
| Weekender (Victron + Battle Born), RSP200DC N-type | 1 | 37.4 V | 41.1 V | 100 V |
| Full-timer (Victron + Battle Born), RSP200D G3 | 3 | 69.0 V | 75.8 V | 150 V |
| Full-timer (Victron + Battle Born), RSP200DC N-type | 3 | 112.3 V | 123.3 V | 150 V |
| Off-grid (Victron + Battle Born), RSP200D G3 | 2 × 2 strings | 46.0 V | 50.5 V | 150 V |
| Off-grid (Victron + Battle Born), RSP200DC N-type | 2 × 2 strings | 74.9 V | 82.2 V | 150 V |
| Weekender (Value mix), RSP200D G3 | 1 | 23.0 V | 25.3 V | 100 V |
| Weekender (Value mix), RSP200DC N-type | 1 | 37.4 V | 41.1 V | 100 V |
| Full-timer (Value mix), RSP200D G3 | 3 | 69.0 V | 75.8 V | 150 V |
| Full-timer (Value mix), RSP200DC N-type | 3 | 112.3 V | 123.3 V | 150 V |
| Off-grid (Value mix), MEGA 200 | 4 | 87.2 V | 99.4 V | 150 V |
Voc rises 0.28% per degree below 25 °C (Renogy datasheet). Renogy sells two very different panels under one 200 W name: the G3 (23 V) and the N-type RSP200DC (37.44 V). Three N-types in series is 123 V cold, which is why the Full-timer kits use a 140 or 150 V controller rather than a 100 V one, and four would be 164 V, which is why the Off-grid kits on Renogy panels run two strings of two. Rich Solar does not publish the MEGA 200's coefficient, so its rows use the NEC 690.7 table factor of 1.14; four of them in one string would be 99 V on a 100 V controller, too close, so the Rich Solar Off-grid kit also runs two strings of two.
Fuses in each kit
| Kit | String fuse | Inverter current | Inverter fuse | Cable |
|---|---|---|---|---|
| Weekender (Renogy) | 20 A for the RSP200D G3, 15 A for the RSP200DC N-type 11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A | 92 A | 150 A (maker's figure; 125% rule gives 125 A) | 4 AWG, 160 A at 105 °C |
| Full-timer (Renogy) | 20 A for the RSP200D G3, 15 A for the RSP200DC N-type 11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A | 184 A | 250 A | 1/0 AWG, 285 A at 105 °C |
| Off-grid (Renogy) | 20 A for the RSP200D G3, 15 A for the RSP200DC N-type 11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A | 276 A | 400 A | 4/0 AWG, 445 A at 105 °C |
| Weekender (Rich Solar) | 20 A 11.6 A × 1.56 = 18.1 A | 92 A | 150 A (maker's figure; 125% rule gives 125 A) | 4 AWG, 160 A at 105 °C |
| Full-timer (Rich Solar) | 20 A 11.6 A × 1.56 = 18.1 A | 184 A | 250 A | 1/0 AWG, 285 A at 105 °C |
| Off-grid (Rich Solar) | 20 A 11.6 A × 1.56 = 18.1 A | 276 A | 400 A | 4/0 AWG, 445 A at 105 °C |
| Weekender (Victron + Battle Born) | 20 A for the RSP200D G3, 15 A for the RSP200DC N-type 11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A | 92 A | 150 A (maker's figure; 125% rule gives 125 A) | 1/0 AWG, 285 A at 105 °C |
| Full-timer (Victron + Battle Born) | 20 A for the RSP200D G3, 15 A for the RSP200DC N-type 11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A | 147 A | 300 A (maker's figure; 125% rule gives 200 A) | 4/0 AWG, 445 A at 105 °C |
| Off-grid (Victron + Battle Born) | 20 A for the RSP200D G3, 15 A for the RSP200DC N-type 11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A | 221 A | 400 A (maker's figure; 125% rule gives 300 A) | 4/0 AWG, 445 A at 105 °C |
| Weekender (Value mix) | 20 A for the RSP200D G3, 15 A for the RSP200DC N-type 11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A | 92 A | 150 A (maker's figure; 125% rule gives 125 A) | 4 AWG, 160 A at 105 °C |
| Full-timer (Value mix) | 20 A for the RSP200D G3, 15 A for the RSP200DC N-type 11.05 A × 1.56 = 17.2 A; 6.85 A × 1.56 = 10.7 A | 184 A | 250 A | 1/0 AWG, 285 A at 105 °C |
| Off-grid (Value mix) | 20 A 11.6 A × 1.56 = 18.1 A | 276 A | 400 A | 4/0 AWG, 445 A at 105 °C |
Wire gauge for 12 V runs (3% drop, copper, 105 °C insulation)
| Load | 5 ft one way | 10 ft one way | 15 ft one way | 25 ft one way |
|---|---|---|---|---|
| 10 A | 12 AWG | 12 AWG | 10 AWG | 8 AWG |
| 20 A | 12 AWG | 8 AWG | 6 AWG | 4 AWG |
| 30 A | 10 AWG | 6 AWG | 6 AWG | 2 AWG |
| 50 A | 8 AWG | 4 AWG | 2 AWG | 1/0 AWG |
| 100 A | 4 AWG | 2 AWG | 1/0 AWG | 4/0 AWG |
| 150 A | 2 AWG | 1/0 AWG | 2/0 AWG | 4/0 AWG |
Ampacity from 33 CFR 183.425 Table 5; resistance from Blue Sea Systems' catalog; 3% drop is Blue Sea's rule for critical circuits. Length is one way; the arithmetic uses the round trip.
The rules, with their sources
- 12.8 V and 1,280 Wh per 100 Ah. LiTime's own spec for its 100 Ah LiFePO4. LiTime
- 80% usable, LiFePO4 only. LiTime rates 4,000 cycles at 100% and 6,000 at 80%; Battle Born allows 100%. We plan at 80% for a long life and a reserve, and we size for lithium only: lead-acid gives up half its capacity and most of its life for the same money. LiTime, Battle Born
- 85% inverter efficiency. Renogy's P2 manual states over 85% at full load; Victron's Phoenix tops out at 91 to 92%. We use the floor. Renogy, Victron
- Battery: Wh × days of autonomy ÷ volts ÷ usable depth. The IEEE 1013 and Sandia stand-alone PV form. We use no cold derate: LiFePO4 is rated at 25 °C and its BMS stops charging below about 0 °C, so plan on less in a freezing cabin. Sandia handbook, Victron LFP datasheet
- Days of autonomy. AS/NZS 4509.2 plans 2 days with an automatic generator, 2 to 3 with a manual one, 4 to 5 with none; IEEE 1562 plans 5 to 7 for non-critical loads. The buttons offer 1 to 3 because an RV has an engine and shore power behind it; pick more for a week in one place. GSES on AS/NZS 4509.2, SunWize on IEEE 1562
- Panels: Wh × 1.2 ÷ sun hours ÷ 0.86 ÷ 0.92. IEEE 1562's array-to-load ratio is 1.1 to 1.2 for non-critical loads and 1.3 to 1.4 for critical ones; we take 1.2. PVWatts v5's default system losses are 14% (soiling 2, shading 3, mismatch 2, wiring 2, connections 0.5, light-induced degradation 1.5, nameplate 1, availability 3). Victron rates LiFePO4 round-trip efficiency at 92%. Together that is 0.79 of nameplate reaching the battery. IEEE 1562, PVWatts losses, Victron
- Battery BMS must carry the inverter. Every LiFePO4 has a BMS with a continuous discharge limit (100 A on a 100 Ah Renogy Pro, Battle Born or LiTime; 200 A on a 200 Ah). The bank's limit, BMS amps × batteries in parallel, must cover the inverter's full-load draw, W ÷ 12.8 V ÷ 0.85: 184 A for 2,000 W, 276 A for 3,000 W. That is why the Full-timer runs two 100 Ah in parallel and the Off-grid four, and why one 400 Ah with a 250 A BMS is not in any kit. Renogy, Battle Born
- Inverter: 120 V loads that run together × 1.25. The NEC continuous-load rule (210.20, 215.2): equipment serving a continuous load is rated at 125% of it. Motor starts are checked against the inverter's 2× surge rating. NEC
- Peak sun hours by region. NREL PVWatts and NSRDB figures as published by city, state and university bodies; December values from the same reports. Size for the worst month you camp in. All five sources
- MPPT amps = panel W ÷ 14.4 V. Victron's nominal PV power ratings (700 W on the 50 A) are exactly that arithmetic; a controller clips extra panel power safely. Victron
- Cold Voc. The controller's PV limit must exceed the string's open-circuit voltage at the coldest morning; Renogy's coefficient is −0.28% per °C; NEC Table 690.7 gives 1.14 for −10 °C. Victron manual, Renogy datasheet, NEC 690.7
- String fuse at 156% of Isc. NEC 690.8: 125% for max current, 125% again for continuous duty. EC&M on NEC 690.8
- Inverter fuse and cable. The maker's manual rules; Renogy specifies 150, 250 and 400 A with 4, 1/0 and 4/0 AWG. The 125% continuous-load rule lands on the same sizes. Renogy P2 manual
- Ampacity and 3% drop. 33 CFR 183.425 Table 5 for how much a wire may carry; Blue Sea Systems for the 3% rule and resistance per 1,000 ft. 33 CFR 183.425, Blue Sea
- Alternator charging: 640 Wh an hour of driving. Victron's Orion XS 12/12-50 delivers 50 A; at 12.8 V that is 640 Wh an hour. The charger tapers as the battery fills, so we cap it at 8 h a day. Victron technical data
- Month-by-month sun from your ZIP. NREL's PVWatts v8 model, flat panel, with the hourly sun reported as peak sun hours; the 14% losses, battery efficiency and array-to-load ratio above are applied after. The five regions are the fallback. PVWatts
- Roof fit. Panels laid out at their datasheet size (Renogy G3 58.7 × 27.5 in, RSP200DC 49.7 × 30.1 in, Rich Solar 58.7 × 26.8 in) with 2 in between, both orientations tried. The rig presets are rough clear-space figures, not maker numbers.
- MPPT over PWM. Victron's white paper measured PWM at 19% less harvest at 25 °C, worse when cold or shaded. Victron white paper
What we could not source from a maker and left out: an induction cooktop's draw, the 12 V heating element of an absorption fridge (dealer figure only, and nobody should run one on 12 V), rooftop AC start-up current, and a manufacturer's number for the flat-versus-tilted penalty. The 0.75 derate, the 1.25 inverter headroom and every "hours a day" are planning conventions, labelled as such.
Every page we read, checked 2026-10-13
66 sources
- Portable fridge: Dometic CFX3 55 (12 V, 53 L) (14 W): www.dometic.com/en-ae/professional/product/dometic-cfx3-55-9600025319
- Portable fridge: Dometic CFX3 35 (12 V, 36 L) (13 W): www.dometic.com/en-ae/professional/product/dometic-cfx3-35-9600025317
- Portable fridge: Dometic CFX3 75DZ, both zones as fridge (18 W): www.dometic.com/en-ae/product/dometic-cfx3-75dz-9600025321
- Portable fridge: Dometic CFX3 95DZ, both zones as fridge (23 W): www.dometic.com/en-ae/professional/product/dometic-cfx3-95dz-960002532…
- Portable fridge: ICECO VL45 (12 V, 45 L) (14.5 W): icecofreezer.com/products/iceco-vl45-portable-refrigerator-freezer
- Portable fridge: Galanz 9.8 cu ft residential top-freezer (120 V) (33.3 W): www.energystar.gov/productfinder/product/certified-residential-refrige…
- LED lights: Thin-Lite LED186P on low (per fixture) (4.32 W): backwoodssolar.com/product/thin-lite-led186p-48-led-fixture/
- LED lights: HitLights 12 V COB LED strip (per foot) (3.048 W): hitlights.com/products/premium-12v-cob-led-strip-light-single-color-ul…
- Water pump: SHURflo 4008 Revolution 3.0 GPM (64 W): defender.com/assets/pdf/shurflo/pds-4008-101-x65.pdf
- Water pump: SHURflo 4048 High Flow 4.0 GPM (at its maximum draw) (128 W): www.pentair.com/en-us/products/residential/water-supply-disposal/recre…
- Phones: Phone on a 20 W USB-C charger (20 W): www.apple.com/shop/product/MHJA3AM/A/20w-usb-c-power-adapter
- Built-in fridge: Dometic DMC4101 10 cu ft (12 V) (156 W): www.dometic.com/en-us/us/products/food-and-beverage/refrigerators/rv-r…
- Water heater: Truma AquaGo Comfort (32 W): www.truma.com/us/boondocking-with-truma-aquago/
- Water heater: Girard GSWH-2 (38 W): www.lippert.com/girard-gswh-2-water-heater-2gwham-2022107534
- Roof vent fan: MaxxAir MaxxFan Deluxe on low (18 W): nomadicsupply.com/maxxair-maxxfan-deluxe-camper-roof-vent-fan-white-05…
- Furnace blower: Suburban NT-16 / NT-20 (16,000 to 20,000 BTU) (36 W): atctrailers.com/wp-content/uploads/2025/04/Suburban_Service_Manual.pdf…
- CPAP: ResMed AirSense 10, device only (7 W): document.resmed.com/documents/products/machine/air10-lumis-series/Powe…
- CPAP: ResMed AirSense 11 with humidifier and heated tube (56.1 W): document.resmed.com/documents/products/machine/airsense-11/user-guide/…
- Cabin fan: Caframo Sirocco II on low (1.5 W): ecofan.caframobrands.com/7010cawbx.html
- Hair dryer: Conair 247VHN 1875 W (1875 W): www.conair.com/powerful-drying-%26-styling-hair-dryer/247VHN.html?lang…
- Laptop: MacBook Air (30 W adapter) (30 W): support.apple.com/guide/macbook-air/apd3a37305b7/2023/mac/14
- Laptop: MacBook Pro 14-inch (96 W adapter) (96 W): www.apple.com/shop/product/MW2L3AM/A/70w-usb-c-power-adapter
- Starlink: Starlink Mini (12 V direct) (30 W): starlink.com/public-files/specification_sheet_mini_x.pdf
- Starlink: Starlink Standard (through the inverter) (87 W): starlink.com/public-files/specification_sheet_standard.pdf
- Cell router: Peplink MAX BR1 Pro 5G (12 V direct) (8 W): download.peplink.com/resources/br1_pro_5g_datasheet.pdf
- TV: Samsung 32-inch UN32M4500 (48 W): www.shi.com/product/34933195/Samsung-UN32M4500BF-32-inch-Diagonal-Clas…
- TV: Sansui 43-inch LE-43KA1 4K (45.14 W): www.energystar.gov/productfinder/product/certified-televisions/details…
- TV: Samsung 43-inch QN90D Neo QLED (63.4 W): www.energystar.gov/productfinder/product/certified-televisions/details…
- Microwave: Furrion 0.9 cu ft RV microwave (1350 W): furrion.com/products/0-9-cu-ft-solo-microwave
- Induction cooktop: Duxtop 9100MC 1800 W (1800 W): www.thesecura.com/product/duxtop-1800w-portable-induction-cooktop-coun…
- Induction cooktop: NuWave PIC Flex Pro 1400 W (1400 W): www.nuwavenow.com/products/nuwave-pic-flex-pro-induction-cooktop
- Pressure cooker: Instant Pot Duo 6 qt (1000 W): instantpot.com/collections/ip-6qt/products/instant-pot-duo-6qt-multi-u…
- Air fryer: COSORI Pro 5.8 qt (CS358-AF) (1700 W): cosori.com/cdn/shop/files/D3_01.08_M1_CS358-AF_2021-11-01_PRINT_US_en.…
- Rooftop AC: Dometic Brisk II 13,500 BTU (1670 W): dometic.com/en-us/us/products/climate/air-conditioners/rv-air-conditio…
- Rooftop AC: Dometic Penguin II 13,500 BTU (low profile) (1731 W): dometic.com/en-us/us/products/climate/air-conditioners/rv-air-conditio…
- Rooftop AC: Furrion Chill HE 13,500 BTU (1450 W): furrion.com/products/13-5k-he-rooftop-unit-for-furrion-chill-air-condi…
- Rooftop AC: Furrion Chill HE 15,000 BTU (1720 W): www.lippert.com/furrion-chill-he-rv-roof-air-conditioner-r32-15k-btu-w…
- Space heater: Lasko 754200 on high (1500 W): lasko.com/products/lasko-1500w-electric-ceramic-space-heater-with-adju…
- LiTime 12 V 100 Ah LiFePO4 spec (12.8 V nominal, 1,280 Wh, cycle life by depth of discharge): www.litime.com/products/litime-12v-100ah-lifepo4-lithium-battery-built…
- Battle Born BB10012 cut sheet (100% DoD, charge voltages): battlebornbatteries.com/wp-content/uploads/2020/06/BB10012-Cut-Sheet-1…
- Battle Born, how much solar per 100 Ah: battlebornbatteries.com/blogs/articles/how-much-solar-do-i-need-for-my…
- Renogy battery bank sizing guide (days of autonomy): www.renogy.com/blogs/buyers-guide/how-to-size-your-battery-bank-to-ext…
- Renogy P2 inverter manual (surge, efficiency, battery fuse and cable table): ca.renogy.com/content/manual/INVT-P2-Manual.pdf
- Renogy RSP100D-BK panel datasheet (Voc temperature coefficient, series fuse): eu.renogy.com/content/RSP100D-BK-G2%20Datasheet.pdf
- Renogy RSP200D G3 panel datasheet (Voc 23 V, Isc 11.05 A, 20 A series fuse): ca.renogy.com/content/Datasheet/RSP200D-G3%20Datasheet.pdf
- Renogy 16BB N-type 200 W panel, RSP200DC (Voc 37.44 V, Isc 6.85 A, 15 A series fuse): fr.renogy.com/en/products/renogy-16bb-n-type-200-watt-24v-solar-panel
- Rich Solar MEGA 200 panel page: richsolar.com/products/200-watt-solar-panel
- Renogy Rover 40 A MPPT spec (100 V PV limit, 520 W at 12 V): www.renogy.com/rover-40-amp-mppt-solar-charge-controller/
- Victron SmartSolar 100/30 and 100/50 datasheet (rated current, nominal PV power, 100 V limit): www.victronenergy.com/upload/documents/Datasheet-SmartSolar-charge-con…
- Victron SmartSolar manual, installation (cold Voc, Vbat + 5 V start, battery fuse): www.victronenergy.com/media/pg/Manual_SmartSolar_MPPT_100-30__100-50/e…
- Victron white paper, PWM or MPPT: www.victronenergy.com/upload/documents/White-paper-Which-solar-charge-…
- Victron Phoenix inverter datasheets (continuous, peak, efficiency, idle draw): www.victronenergy.com/upload/documents/Datasheet-Phoenix-Inverter-VE.D…
- 33 CFR 183.425 Table 5, conductor ampacity: www.govinfo.gov/content/pkg/CFR-2012-title33-vol2/pdf/CFR-2012-title33…
- Blue Sea Systems, voltage drop and wire sizing (3% rule): www.bluesea.com/support/reference/535/Voltage_Drop_in_Conductor_-_Wire…
- Blue Sea Systems catalog, ampacity and resistance table: catalog2015.bluesea.com/files/assets/basic-html/page-138.html
- NEC 690.7 and 690.8 as reproduced by Mike Holt (cold correction factors, 125% rule): www.mikeholt.com/instructor2/img/product/pdf/14SOLB-1229-sample.pdf
- EC&M, calculating current ratings of PV modules (the 156% rule): www.ecmweb.com/renewables/article/20896977/calculating-current-ratings…
- Stäubli MC4 connector datasheet (current ratings): docs.vekto.nl/media/staubli/staubli-staubli-mc4.pdf
- Peak sun hours, Pacific Northwest (Seattle area, 1° tilt): permitbulletin.mercerisland.gov/public/2509-066/SUB1/solar%20calculati…
- Peak sun hours, Northeast (Dover NH, 10° tilt): publicrecords.dover.nh.gov/FileDownload/72261/Public_Meetings/0
- Peak sun hours, Mid-Atlantic and Midwest (Richmond VA horizontal; Kirksville MO December): efis.psc.mo.gov/Document/Display/280931
- Peak sun hours, South and Texas (McAllen TX, 5° tilt): interchange.puc.texas.gov/Documents/56768_8_1443203.PDF
- Peak sun hours, Desert Southwest (Prescott AZ): www.yc.edu/V6/facilities/docs/Solar_Overview.pdf
- NREL PVWatts v8 API (month-by-month solar resource for a ZIP code): developer.nrel.gov/docs/solar/pvwatts/v8/
- Victron Orion XS 12/12-50 technical data (50 A alternator charger): www.victronenergy.com/media/pg/Orion_XS/en/technical-data.html
- Rich Solar MEGA 200 (58.7 × 26.8 in) and Renogy RSP200D G3 (58.7 × 27.5 in) and RSP200DC (1262 × 764 mm) panel sizes: richsolar.com/products/200-watt-solar-panel
RV solar questions
How much solar do I need for my RV?
Add up a day of use in watt-hours, multiply by 1.2 (the IEEE 1562 array-to-load ratio for non-critical loads), then divide by your region's peak sun hours, by 0.86 for PVWatts' default system losses and by 0.92 for the battery's round-trip efficiency. A fridge, lights, pump, fan on low and phones is about 650 Wh a day, which one 200 W panel covers at 5 peak sun hours. Starlink, a laptop, a TV and a microwave push that to about 1,500 Wh and 600 W of panels.
Can I run my RV air conditioner on solar?
Rarely. A 13,500 BTU rooftop unit draws about 1,670 W, so eight hours is roughly 14 kWh, eleven 100 Ah lithium batteries, and about 3,600 W of panels to refill. That does not fit on an RV roof. Run the AC on shore power or a generator and size solar for everything else.
Do I need MPPT or is PWM fine?
MPPT. Victron's own test shows a PWM controller harvesting 19% less than MPPT from the same panel at 25 °C, and the gap grows in cold weather, low light and partial shade. The price difference is small next to the panels it wastes.
Should I wire panels in series or parallel?
Series for most RVs: one string, one fuse, thin wire, and the controller starts earlier in the morning. The limit is the controller's PV voltage: add up the panels' open-circuit voltage and multiply by about 1.1 for a cold morning. Three 23 V panels in series is 76 V cold, fine on a 100 V controller; three of Renogy's 37 V N-type panels is 123 V, which needs a 140 or 150 V controller.
What size fuse goes between the battery and the inverter?
The one the inverter maker specifies, which for Renogy's P2 line is 150 A for 1,000 W, 250 A for 2,000 W and 400 A for 3,000 W. The arithmetic agrees: 2,000 W at 12.8 V and 85% efficiency is 184 A, times the 125% continuous-load rule is 230 A, so a 250 A fuse on 1/0 AWG cable rated 285 A.
Know what to buy before you climb on the roof.
Tap your loads, read the numbers, pick the kit.
Size my systemNot ready to wire a roof? A power station and a folding panel covers weekend trips with no installation.